INSTALLATION INSTRUCTIONS
EPT031055 Issue 2 September 2017 2-51
SHUTTER TIMING
1
1
2
2
3
3
4
4
D D
C C
B B
A A
Date Name Date Name
Ind. Chan.No. Changing Processed Reviewed
Title:
Project:
No.: 190028
Laser  /  shutter  timing
Fibre  laser
Fiber_shutter_timing_customer-1_11-190028c.SchDoc
Date
Date  see  box
File:
Version: See  box Page                  of Size: A411
D-22547  Hamburg
Germany
Sator  Laser  GmbH
Fangdieckstraße  75a
©  Sator  Laser  GmbH
Domino  Group
omino  Laser  GmbH
angdieckstraße  75a
-22547  Hamburg
Germany
©  Domino  Laser  GmbH
Timing        a00    28.11.13        HK
ow  190024      a01:  With  number  and  new  location    11.12.13      HK
ow  190028      a01:    Version  with  and  without  shutter      27.02.14    HK
  b10:      Deleted  print  timing  activities.  Deleted  Safety  to  BCP7  and  Laser  PSU  on  lines. 
                          Dividing  shutter  diagram  with  /  without  lock  version.  Document  now  for  all  lasers.             
                                    18.08.14      HK
  c11:      TÜV  version  with  shutter  an  safety  output  test  cycles  time  delay                  10.11.14        HK
\\emea\group\Sator\Projects\Fibre_Laser\Shutter_Safety_Concept\Docu_Collection\DXP
X69  Guard  door
X69:7  Start
Laser  PSU  on
BCP7  RDY
100ms  min
200ms
5s
open
Version  laser  without  shutter
100ms  min
200ms
5s
100ms  min
2.5s
5.4s
40ms
40ms
150ms
Normal  workingInitial  start  sequence
Version  laser  with  shutter    (standard  mode)
100ms  min
5.4s
40ms
40ms
150ms
Normal  working  /  closing  door  firstInitial  start  sequence
180ms
Version  laser  with  shutter  and  door  lock  (static  mode;  open  by  start  input)
50ms  min  *
*  Unlocking  time  dependig  on  the  locking  device
100ms  min
5.4s
40ms
40ms
150ms
Normal  working  /  Start  command  firstInitial  start  sequence
180ms
Version  laser  with  shutter  and  door  lock  (static  mode,  open  by  door  closing)
50ms  min  *
*  Unlocking  time  dependig  on  the  locking  device
closed
X69  Guard  door
X69:7  Start
BCP7  RDY
open
closed
X69  Guard  door
X69:7  Start
BCP7  RDY
open
closed
X69  Guard  door
X69:7  Start
BCP7  RDY
open
closed
Door  lock
Door  lock
2.5s
2.5s
Shutter  (open)
Shutter  (open)
Shutter  (open)