OPERATION
EPT009665 Issue 2 May 2015 3-51
Standard Parameters
Default Parameters
Parameter Ranges
CAUTION: The sum of the laser on delay and the jump delay
has to be larger than 180 microseconds!
Note: If the marking quality is not sufficient, due to missing vectors or
missing parts of vectors, consider the following rule:
LaserOffDelay < MarkDelay + StepPeriod + 10 μs
Parameter Laser System
F220 i-Tech 10mm scan head
FPE 160
Waveform 0
StepPeriod [μs] 20
JumpDelay [μs] 110
MarkDelay [μs] 120
PolygonDelay [μs] 10
LaserOffDelay [μs] 110
LaserOnDelay [μs] 80
OnPulse 1
Period 40 [25kHz]
MaxVectorLength [mm] 0.2
JumpSpeed [bit/ms] 6000
MarkSpeed [bit/ms] 1000
Parameter Laser System
F220 i-Tech 10mm scan head
StepPeriod [μs] 10..100
JumpDelay [μs] 0..500
MarkDelay [μs] 0..500
PolygonDelay [μs] 10..500
LaserOffDelay [μs] 10..500
LaserOnDelay [μs] 0..500
MaxVectorLength [mm] 0..100
JumpSpeed [bit/ms] 1000..11000
MarkSpeed [bit/ms] 10..17000

Table of Contents