MAINTENANCE AND FAULT FINDING
EPT009665 Issue 2 May 2015 5-33
Changing the Chemical Pad (DPX2000)
WARNING: Full protective clothing must be worn and
correct disposal methods used immediately.
(1) Turn off the extractor.
(2) Open the cabinet door.
(3) Remove the Super Filter Bag.
(4) Lift the Chemical Pad out of the bottom of the compartment and
dispose of using approved procedures.
(5) Place a new Chemical Pad onto the bottom of the compartment.
(6) If required, fit a new Filter Bag as on page 5-31.
(7) Close and lock the cabinet door, turning the catch fully clockwise.