2.2.2 Controlling a Gate Operator and Pedestrian Gate (or Door)
When controlling a gate operator and pedestrian gate (or door), relay 1 is typically used to control the
gate operator while relay 2 is typically used to control the door or gate. Note that the electric strike
and the magnetic lock are powered from their own power supply. The relay 2 contact is set to either
normally open (NO) for electric strikes, or normally closed (NC) for magnetic locks by placing the
relay 2 contact shorting bar on either the NO or NC pins.
A variation of this diagram is for the system to control two doors or two gates.
13 14 15 16 17
Relay 2 COM
Relay 2
Relay 1 COM
Relay 1 NO
Relay 1 NC
AND
OR
Gate Operator
Electric Strike
Magnetic Lock