Reading and Setting Display Units
The WEDGE has four choices for display units:
°F, PSI
°C, Bars
°C, kPa
°C, Kg/cm2
To determine which units the WEDGE has been configured for:
1. With the ignition switch turned “OFF”
2. Press and hold the "Service Air" Switch
3. Turn the ignition switch directly to the crank position.
4. Hold these switch positions until the numeric display on the WEDGE
goes blank.
5. Release "Service Air" switch, release ignition switch to the "ON"
position.
The current units will be displayed for 2 seconds. The units will be displayed as:
°F, PSI will be displayed as "PSI"
°C, Bars will be displayed as "bAr"
°C, kPa will be displayed as "HPA"
°C, Kg/cm2 will be displayed as "H9C"
To change the units setting:
1. With the WEDGE showing the current units setting, press and release the
"Service Air" switch until the desired units appear on the display.
2. Once it appears, do not release the "Service Air" switch. Keep the switch
pressed until the WEDGE restarts. This will change the units to the desired
selection.
3. Release the "Service Air" switch.
4. Cycle the power using the ignition switch. The machine is now ready to start
and displaying the units selected.