Book: 23227143 (8-24-2010) Rev CPage43
COMPRESSOR CODE 11
Too Many Start Attempts During Auto Start
Troubleshooting Steps
Action Result
Step 1:
Crank machine manually to verify proper operation.
Step 2:
Check engine fuel system for restrictions.
Dirty fuel filters
Clogged Hoses
Air in fuel system
Step 3:
Check the condition of the machine batteries and
verify battery charger is working properly.
Step 4:
Verify machine cold weather kit is working properly
(if equipped).
Explanation:
The WEDGE has made three attempts to start the machine as commanded by the
Auto Start/Stop controller and the machine failed to start.
Effect:
Code 11 is a SHUTDOWN condition and will prevent further cranking. The
Compressor Malfunction light will be on solid, and Code 11 will be displayed.