Book: 23227143 (8-24-2010) Rev CPage47
COMPRESSOR CODE 32
Troubleshooting Steps
Action Result
Step 1:
Check all harness connections between WEDGE
and RT2 temperature sensor.
Repair harness as needed
Step 2:
Disconnect RT2 from harness and plug thermistor
simulator (Part No. 22073878) into the harness
connector. Check WEDGE diagnostic display 6 to
verify temperature value is between -3
o
F and -13
o
F.
If temperature value on display
6 is not between -3
o
F and
-13
o
F, check for WJDing
problems
If temperature value on display
6 is between -3
o
F and -13
o
F,
replace RT2 temperature
sensor
Step 3:
If Steps 1 and 2 checkout OK, replace WEDGE.

Table of Contents