Data output message format 1- "lb & oz":
STX POL DATALB lb DATAOZ oz grs/net ST* CR+LF
5.3.2 Format 2
Data output message format 2- "lb", "kg", "oz" and "g":
STX POL DATA SP lb/kg/oz/g ST* CR+LF
Data output message format 2- "lb & oz":
STX POL DATALB SP lb SP DATAOZ SP oz ST* CR+LF
5.3.3 Format 3
Data output message format 3- "lb", "kg", "oz" and "g":
STX POL DATA SP lb/kg/oz/g grs/net ST* CR+LF
STX "TARE :" SP POL DATA SP lb/kg/oz/g SP* CR+LF
Data output message format 3- "lb & oz":
STX POL DATALB SP lb SP DATAOZ SP oz grs/net ST* CR+LF
STX "TARE :" SP POL DATALB SP lb SP DATAOZ oz ST* CR+LF
5.3.4 Format 4 DGH Module Format.
"$1AO" +/- DATA(7) CR+LF
Note: The baud rate and data bits default to interface to the DGH module. Also when
exiting set up, the 8000 sends a set up string to the DGH module so it can be utilized
immediately.
5.3.5 Format 5 A/D Printer Format.
(no lb oz, set 7 data bits, even parity)
OL/ST/US NT/GS +/- DATA lb/kg/oz/g CR+LF
5.3.6 Format 6 SSP/DLP Printer Format. *Continuous mode only
|l| FR”LF1” |l?| weight data |I| units |l| grs/net |l| P1 |l
5.4 Definition of Terms
STX = Non-recording "START OF TEXT" character (02H)
POL = Single character polarity; space for positive, minus (-) for negative