Problem : Scale will not run for a full 40 hours on a charge.
Remedy : Try charging for a longer time. If there is no improvement it may be
necessary to replace the battery.
Problem : Scale is "dead"; it won't turn on.
Remedy : Plug the scale into a 115VAC (220VAC if applicable) receptacle and try
again. If there is still no response, it indicates possible PCB problems.
Contact the factory.
If you still have a problem with your Model 8000, please call your authorized Doran
Scales dealer or contact Doran Scales' Service Department at 1-800-262-6844 for
further assistance.
DO NOT, under any circumstances, return a scale or part to Doran Scales without first
obtaining an RMA (Return Material Authorization) from the service department.
7.2 CONFIGURATION PRINTOUT For revision 3.6 and greater.
1. Press and hold ‘PRINT’ during power up to print a configuration list.
2. “CFGPRT" will display while the configuration list is printing.
This list will include all of the parameters and the settings for each parameter. This is
provided for viewing the configuration without accessing the programming mode of the
scale.
7.3 Initial Parameter Review For revision 4.2 and greater.
1. Press and hold ZERO then press and release ON/RESTART. Hold ZERO until
‘CFGdSP’ displays.
2. The parameters will automatically scroll through holding at each function for 2-3
seconds.
3. Function or parameter displays on the left and the Option displays on the right.
7.4 RESETTING PARAMETERS
To reset the parameters to factory default settings:
1. Turn the unit off and switch the OPERATE/CALIBRATE switch to CALIBRATE.
2. While pressing and holding the ZERO button, turn the scale on by pressing the
ON/RESTART button.
3. The 8000 will go through a display test and then display the message "Er Fuc".
Parameters have been defaulted.
4. Next the 8000 will display "Rel 0".
5. Release the ZERO button. Parameter settings will be saved.
6. Return the CALIBRATE switch to OPERATE position. The 8000 will now operate
with default parameter settings.