Replace the access panel making sure that all of the 8000's gaskets are in place to
maintain the 8000's water resistant integrity.
6.7 ERROR CODE TABLE
Error Code : ErrEEP-Possible non-volatile memory loss.
Cause : Memory has been corrupted by a power line problem or ESD (Electrostatic
Discharge).
Remedy : Enter calibration mode upon power up and reset parameters. Parameters will
be reset to their default settings. Verify calibration.
Error Code : Er nSt-Scale not stable.
Cause : Vibration/air currents affecting platform or possible trouble with the load cell or
A/D PCB.
Remedy : Isolate platform from the vibration or replace defective load cell or PCB.
Error Code : Er C0U-Load cell output too low for Cal 0.
Cause : Negative zero shift of load cell or trouble with A/D PCB.
Remedy : See Section 6.3.
Error Code : Er C0E-Load cell output too high for Cal 0.
Cause : Positive zero shift of load cell or possible problem with A/D PCB.
Remedy : Make sure platform is empty. See Section 6.3.
Error Code : Er SFO-Load cell output swing too large.
Cause : Gain setting on DIP switches too large or load cell is too small for selected
scale capacity.
Remedy : See Section 6.4.
Error Code : Er SFU-Load cell output too small.
Cause : Gain setting on DIP switches is too small or load cell is too large for selected
capacity.
Remedy : See Section 6.4.
Error Code : Er SPO-Selected span value is over 3000 or 6000 full scale counts.
Cause : Improper setting of cal span value.
Remedy : Recheck test weight value and reset span.
Error Code : Er SPU-Selected span value is less than 600 counts full scale.
Cause : Test load too light or improper cal span setting.