6.2 Terminal assignment for an Upgrade Card barrier-free WC
The door system must be equipped with the following components:
• Closed current door opener or a suitable motor-driven panic lock
• On the inside with a door handle and a knob on the outside
• Flat pushbutton on the inside and outside
• On the outside: a status display "free/occupied"
• On the inside: a status display "occupied"
0 V
B
A
8 – 24 V DC/AC + 5 %
+ 24 V
+ 24 V
Signal input
0 V
+ 24 V
COM
Locking relay
max. 1 A/48 V DC/AC
NO
NC
0 V
Locking response
0 V
+ 24 V
Signal input
0 V
0 V
+ 24 V
0 V
Signal input
0 V
Partiall open
Permanent open
Exit only
Automatic
Off
NC
NO
Max. 1 A/48 V DC/AC COM
0 V
Signal input
Test output
+ 24 V
0 V
Signal input
Test output
+ 24 V
0 V
Night/bank
Shutdown
drive function
Smoke
detector
Night/bank
Program
switch
Status
relay
Pulse
external
Pulse
internal
Safety sensor
hinge side
Safety sensor
side opposit to hinge
DCW
Emergency buttons can be installed
optionally on the inside and outside.
dormakaba recommends to include the
barrier-free WC into an emergency call
system provided by the customer.
Activation forced flushing
1 s pulse, 24 V DC
free
occupied
ED 100, ED 250
—