DRAINING THE DOSATRON
In order to perform thorough maintenance on the DOSATRON, or to protect it
from frost, it may be necessary to drain it.
Turn off the water supply and allow the pressure to drop to zero.
Remove the injection assembly ( see Removing/refitting the injection
assembly, page 44).
Unscrew the top cover and take out the motor.
Disconnect the water inlet and outlet connections.
Empty the main body after removing it from the mounting bracket.
Refit, once you have cleaned the motor cover seal