Operation
Calibration menu functi
ons
●
Press the
key to cancel the active function.
—
If no key is pressed for 10 minutes, the devi
ce returns automatically to measuring mod
e.
Fresh air calibration, refer to page
36
1-button calibration, refer to page
38
Single gas calibration, refer to page
40
16
18
Table of Contents
Default Chapter
2
Table of Contents
2
For Your Safety
4
Safety Symbols Used in These Technical Manual
4
Intended Use
5
Tests and Approvals
6
Marking
6
Intended Operating Area and Operating Conditions
7
What Is What
8
Front Panel
8
Rear Panel
8
Display
8
Special Symbols
9
Configuration
10
Standard Gas Configuration
10
Standard Device Configuration on Delivery
10
Activating the Device
11
Operation
12
Switching on the Device
12
Switching off the Device
12
Before Entering the Workplace
13
During Operation
13
Calling the Info Mode
14
Calling the Quick Menu
15
Possible Functions of the Quick Menu
15
Calling the Calibration Menu
16
Calibration Menu Functions
17
Identifying Alarms
18
Concentration Pre-Alarm A1
18
Concentration Main Alarm A2
18
STEL / TWA Exposure Alarm
18
Battery Pre-Alarm
19
Battery Main Alarm
19
Device Alarm
19
End of Operation
19
Pump Operation
20
With Dräger X-Am 125 Pump
20
With Hand Pump Adapter and Rubber Ball Pump
20
Observe the Following During Pump Operation Mode
20
Configuring the Device
21
Read Data Base and Display Graphically
22
Faults, Cause and Remedy
23
Warning Messages
23
Fault Messages
25
Maintenance
28
Maintenance Intervals
28
Carrying out the Function Test with Gas (Bump Test)
29
Manual Implementation Without the Documentation of Result in the Device
29
Memory
29
Menu Implementation with the Documen-Tation of Results in the Device Memory
30
Automatic Implementation with the Bump Test Station
33
Calibrating / Adjusting the Device
35
Carrying out the Fresh Air Calibration
36
Carry out the 1-Button Calibration
38
Calibrating/Adjusting the Sensitivity for a Single Measuring Channel
40
Replacing the Batteries / Rechargeable Batteries
42
Charging the Rechargeable Batteries
43
Charging with the Multiple Charging Station
43
Adapter
45
Replacing the Sensors
46
Care
48
Disposing of the Device
49
Technical Data
50
Sensor Data
50
Order List
52
Accessories
53
Spare Parts
54
Declaration of Conformity
55
Other manuals for Dräger X-am 2000
Instructions For Use
120 pages
Technical Handbook
60 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Dräger X-am 2000 and is the answer not in the manual?
Ask a question
Dräger X-am 2000 Specifications
General
Brand
Dräger
Model
X-am 2000
Category
Measuring Instruments
Language
English
Related product manuals
Dräger X-AM 2500
20 pages
Dräger Pump X-am 1/2/5000
48 pages
Dräger X-am 7000
100 pages
Dräger X-am 1100
120 pages
Dräger X-am 1700
120 pages
Dräger X-zone 5500
4 pages
Dräger Interlock XT
40 pages
Dräger JM-103
94 pages
Dräger Pac 7000
268 pages
Dräger Pac 5000
3 pages
Dräger Polytron 8700
39 pages
Dräger Polytron 5000
16 pages