LHT52 Temperature & Humidity sensor 35 / 40
It is also possible to connect using DAPLink
Connection:
USB to DAP-LINK GND <--> Program Converter GND pin
USB to DAP-LINK RXD <--> Program Converter D+ pin
USB to DAP-LINK TXD <--> Program Converter A11 pin
In PC, User needs to set serial tool(such as putty, SecureCRT) baud rate to 115200 to access to
access serial console for LHT52. The AT commands are disable by default and need to enter
password (default:123456) to active it. Timeout to input AT Command is 5 min, after 5-minute,
user need to input password again.
Input password and ATZ to activate LHT52,As shown below: