4
4. TECHNICAL CHARACTERISTICS
GENERAL TECHNICAL CHARACTERISTICS
Number of outlets / pumping elements
Nominal output per pump element (20 RMP) *
2,8 cm³/min (0.17 in³/min)
5,2 cm³/min (0.31 in³/min)
0,4 ÷ 2,8 cm³/min (0.02 ÷ 0.17 in³/min) - Adjustable
Integrated By-pass pressure (if present)
320 bar ±30 bar (4641 psi ±435 psi)
2 – 5 – 8 litres (0.53 – 1.32 – 2.11 gallons)
IP65 (IP 69K with special equipment)
CONTROL PANEL CHARACTERISTICS
Includes internal transformer
Maximum Output load capability
Short circuit & Overload protection.
Overload protection on motor and lamp
Integrated Motor protection
Spike voltage protection
Inverted Polarity protection
Memory for parameter storage
Unlimited (no battery requirement)
WARNING: Do not operate the unit outside the specified voltage ranges.
* NOTE:Pump output has been determined at the following conditions: Grease, NLGI 2, Standard
environmental conditions (Temperature 20°C / 68°F, Pressure 1 ATM), Back pressure on outlet 50bar
(735 psi) 12V e 24V voltage.