Appendix 3: Template Programming Tables
Bell Circuit Trouble
[308][302] - Bit 1 Panel Bell Trouble - On
[308][302] - Bit 2 Panel Bell Trouble Restore - On
Fire, Alarm
[308][311] - Bit 3 Fire Trouble - On
[308][311] - Bit 4 Fire Trouble Restore - On
[308][305] - Bit 3 2W Smoke Trouble - On
[308][305] - Bit 4 2W Smoke Trouble Restore - On
Aux Power Supply Trouble
[308][302] - Bit 5 Panel AUX Trouble - On
[308][302] - Bit 6 Panel AUX Trouble Restore - On
[308][332] - Bit 5 Module AUX Trouble - On
[308][332] - Bit 6 Module AUX Trouble Restore - On
TLM Trouble
[308][302] - Bit 3 Panel TLM Trouble - Off
[308][302] - Bit 4 Panel TLM Trouble Restore - On
General System Tamper
[308][101] - Bit 3 Module Tamper Trouble - Off
[308][101] - Bit 4 Module Tamper Restore - Off
General System Supervisory
[308][332] - Bit 3 Module Supervisory Trouble - On
[308][332] - Bit 4 Module Supervisory Restore - On
l Openings & Closings - Sets Residential Dial Reporting Codes for all openings and closings
Openings/Closings Group Openings/Closings Programming
Enable All User Open/Close Reports
[308][201] - Bit 1 User Closing - On
[308][201] - Bit 2 User Opening - On
[308][201] - Bit 5 Special Closing - On
[308][201] - Bit 6 Special Opening - On
[308][202] - Bit 1 Automatic Closing - On
[308][202] - Bit 2 Automatic Opening - On
[308][202] - Bit 3 Automatic Cancel - On
l Zone Alarm Restore Group - Disables all zone alarm restore reporting codes
Zone Alarm Restore Group DLS/Installer Lead In/Out Programming
Restore zone alarm reporting codes
[307][001] - Bit 2 Alarm Restore - Off
[307][002] - Bit 2 Alarm Restore - Off
[307][003] - Bit 2 Alarm Restore - Off
[307][004] - Bit 2 Alarm Restore - Off
[307][005] - Bit 2 Alarm Restore - Off
[307][006] - Bit 2 Alarm Restore - Off
[307][007] - Bit 2 Alarm Restore - Off
[307][008] - Bit 2 Alarm Restore - Off
[307][009] - [128] Bit 2 Alarm Restore - Off
l Installer Lead-in/Lead-out and DLS Lead-in/Lead-out