Section 6: Programming
OFF does not activate if a not networked trouble condition is present.
156 Latched System Event
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
02 Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
04 Fire Alarm
ON: activates with fire alarm, [F] key, fire zones, 2-wire smoke.
OFF: does not activate with fire alarm.
05 Panic Alarm
ON: activates on panic alarm (audible or silent).
OFF: does not activate on panic alarm.
06 Burglary Alarm
ON: activates on burglary alarm.
OFF: does not activate on burglary alarm.
07 Medical Alarm
ON: activates on medical alarm.
OFF: does not activate on medical alarm.
08 Supervisory
ON: activates on supervisory alarm.
OFF: does not activate on supervisory alarm.
09 Priority Event
ON: activates on priority alarm.
OFF: does not activate on priority alarm.
10 Holdup
ON: activates on holdup alarm.
OFF: does not activate on Holdup alarm.
11 Duress Alarm
ON: activates on duress alarm.
OFF: does not activate on duress alarm.
12 Emergency Alarm
ON: activates on emergency alarm.
OFF: does not activate on emergency alarm.
13 Fire Supervisory
ON: activates on fire supervisory alarm.
OFF: does not activate on fire supervisory alarm.
14 Fire Trouble
ON: activates on fire trouble condition.
- 92 -