Section 6: Programming
OFF: does not activate on fire trouble condition.
15– CO Alarm
ON: activates on CO alarm.
OFF: does not activate on CO alarm.
157 System Tamper
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
09 System/Module Tampers
ON: activates when any module tamper condition occurs.
OFF: does not activate when any module tamper condition occurs.
10 Zone Tampers
ON: activates when any zone tamper condition occurs.
OFF: does not activate when zone tamper conditions occur.
161 DC Trouble
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
02 PGM Timer
ON: output remains active until an access code is entered or certain criteria have been met, depending on the PGM
type.
OFF: output remains active until the PGM output timer expires.
09 Battery Low
ON: activates when a low battery trouble occurs.
OFF: does not activate when a low battery trouble occurs.
10 Battery Absent
ON: activates when a battery absent trouble occurs.
OFF: does not activate when a battery absent trouble occurs.
165 Prox Used
01 True Output/Latched Output
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
166 Partition Prox Used
01 True Output/Latched Output
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
175 Bell Prog Access
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
- 93 -