Chapter 4 Programming Descriptions
15
[016] Fourth System Option Code
[017] Fifth System Option Code
[018] Sixth System Option Code
Option Description
[1] ON: the system supervises the AC input and displays a trouble if a failure is detected. OFF: AC Input is not supervised.
[2] ON: the trouble light will flash when an AC trouble is detected. OFF: the trouble light turns on, does not flash.
[3] ON: the keypad blanks (no indicator lights) if a key is not pressed for 30 seconds. OFF: the keypad does not blank.
[4]
ON: a valid user code must be entered to restore normal keypad operation after the blanking.
OFF: pressing any key will return the keypad to normal operation.
[5] ON: keypad backlighting enabled. OFF: keypad backlighting disabled.
[6]
ON: the system temporarily enables the Keypad Blanking feature if an AC failure is detected (to preserve the back-up battery).
OFF: the system will operate as normal.
[7]
ON: the keypad turns ON the Bypass light if zones are bypassed while the system is armed.
OFF: the Bypass light turns OFF when the system is armed.
[8] ON: the system supervises keypad tampers. OFF: the system does not supervise keypad tampers.
Option Description
[1] ON: the system does NOT associate wireless keys to user codes.
OFF: the system will assign user code 17 to wireless key #01, user code 18 to wireless key #02 etc. If the wireless key is used to arm
or disarm, the system will report the Opening or Closing for the associated User Code.
[2] ON: the system logs an RF Jam trouble condition if the condition is present for 5 minutes.
OFF: the system logs the trouble condition after 30 seconds.
[3] ON: the keypads beep if an RF Jam trouble is detected. OFF: the trouble is not announced via the keypad buzzer.
[4] ON: Double Hit Feature enabled. Two alarms from the same zone within the Cross Zone Timer Duration will cause the Police Code
or Cross Zone to be logged and transmitted. NOTE: This feature must be disabled to be DD243 compliant.
OFF: Double Hit Feature disabled. Two alarms from the same zone will not cause the Police Code or Cross Zone to be logged and
transmitted. Two different zones must be in alarm to transmit the Police Code or verify the Cross Zone. This feature only applies to
zones defined as Interior, Instant Stay/Away, Interior Delay, Interior Stay/Away, or Delay Stay/Away (PIR Zones). This is a flexible
extension of the existing Police Code. This feature is directly affected by the Cross Zone Timer.
[5] ON: the system logs and communicates a Late-To-Close event when the auto-arm time comes, but the function has been disabled
(not if auto-arming was caused by the No-Activity Arming feature).
OFF: the system does not transmit or log a Late-To-Close event.
[6] ON: enables the Daylight Savings automatic clock adjustment feature.
OF
F: the system does not automatically adjust the clock for Daylight Savings.
[7] For Future Use
[8] ON: the system only squawks the bell output when the system is armed in the Away mode.
OFF: the system squawks the siren when the system is armed in any mode. (See Section [14], Option [1]).
Option Description
[1] ON: the system only transmits a Test Transmission reporting code if no other event was transmitted to the central station during the
programmed time.
OFF: the system always transmits a Test Transmission reporting code as programmed.
[2] ON: Real-Time Bypass Reporting Enabled. When [][1] is used to bypass a non-24 hour zone, the system immediately logs and
communicates the zone bypass status.
OFF: Real-Time Bypass Reporting Disabled. When [][1] is used to bypass a non-24 hour zone, the system logs and communicates
the zone bypass status after the partition has been armed. Zone bypass statuses for 24-hour zones are still immediately logged and
communicated.
[3]-[4] For Future Use
[5] ON: the keypad buzzer follows the bell output for all alarms. OFF: the system only activates the bell output for all alarms.
[6] ON: when an alarm is detected on a zone (Cross Zone enabled), a timer is started. The alarm is not transmitted and the bell output is
not activated unless a second cross zone enabled zone is violated before the Cross Zone timer times out.
OFF: the system reports all alarms normally and logs and transmits a Police Code reporting code if a second zone alarm is detected
during the armed period.
[7] ON: the system restarts the Exit Delay (one time) if a Delay zone is violated and restored during the exit delay time.
OFF: the Exit Delay does not restart.
[8] ON: the system activates the trouble beeps when an AC trouble is detected.
OFF: the system does not announce AC troubles using the keypad buzzer.