Chapter 4 Programming Descriptions
25
[702] Second International Option Code
[703] Delay Between Dialing Attempts
Program the amount of time (in seconds) the panel will wait between dialing attempts to transmit a reporting event to the central station.
Valid entries are [001] to [255].
[800]-[851] Module Programming
The following program options are used to program different modules that can be connected to the control panel. Refer to the relevant Instal-
lation Manual for installation and programming information.
[801]: PC5400 Printer Module Programming
[802]: PC59xx VOX Module Programming
[803]: Alternate Communicator Programming
[804]: Wireless Programming
[805]: PC5100 Addressable Programming
[851]: TL/GS Module Programming
Special Installer Instructions
[898] Wireless Enrollment
Refer to Section 1.12 Wireless Enrollment Procedure for details.
[899] Template Programming
Selecting [][8] [Installer Code] [899] displays the current 5-digit template programming code. Refer to section 3.1 Template Programming for
details. Refer to Appendix E - Template Programming for a detailed description of available templates and corresponding 5-digit codes.
[900] Panel Version Displayed
Only available with LCD5500 or PK/RFK/WT5500 keypads. The system will display the version of the control panel (e.g., [0470] indicates
panel version 4.70).
[901] Installer Walk Test
The system will turn Installer Walk Test ON. The Ready, Armed and Trouble LED’s will flash rapidly while the test is active. Every time a
zone is violated the system will activate the bell output for two seconds and log the event to the event buffer. To turn Installer Walk Test OFF
enter [901] again. The system automatically terminates the test if there is no zone activity for 15 minutes.
[902] Module Supervision Reset
All modules are automatically detected within one minute after being connected to the Keybus. Enter [902] to clear detected modules if a
module is removed, if PC5108 jumpers are changed, or if a keypad’s slot assignments are programmed. The system will rescan the Keybus
to determine which modules are connected.
Option Description
[1]
ON
: the communicator uses a 33/67 make/break ratio when pulse dialing.
OFF: the system uses a 40/60 make/break ratio.
[2]
ON
: the system dials regardless of the presence of a dial tone after the first attempt.
OFF: the system dials only if a dial tone is detected.
[3]
ON
: changes the Test Transmission Cycle Time to minutes.
OFF: sends a Test Transmission after the programmed number of days.
[4]
ON
: the system accepts 1600Hz handshake pulse formats.
OFF: the system accepts 1400Hz or 2300Hz handshakes.
[5]
ON
: the system generates a tone for 500ms every 2 seconds, indicating digital equipment is making the call vs. a voice call.
OFF: the system does not generate a tone.
[6]
ON
: the tone generated (2100Hz.) indicates that digital equipment is making the call.
OFF: the tone is 1300Hz.
[7]
ON
: the DLS down loading window is 1 hour. OFF: the DLS downloading window is 6 hours.
[8]
ON
: the system activates the bell output if a Failure to Communicate trouble occurs while the system is armed.
OFF: the system does NOT activate the bell output if a Failure to Communicate trouble occurs while the system is armed.
This feature requires a PK55xx or RFK55xx series keypad, v.1.1 or higher.