Loading...
PowerSeries - PC1616/PC1832/PC1864
46
[380] First Communicator Options
[381] Second Communicator Options
[382] Third Communicator Options
* A Call Waiting Cancel on a non-Call Waiting line will prevent successful connection to the central station.
[383] Fourth Communicator Options
[389] TL/GS Module Fault Check Timer
Default: 001 I_______I_______I_______I Enter no. of checks X 3 seconds - valid entries 001 to 255
Opt Def ON OFF
1
Communications Enabled
Communications Disabled
2
Restorals on Bell Time-out
Restorals Follow Zones
3
Pulse Dialing
DTMF Dialing
4
Switch to Pulse Dialing on 5th Attempt
DTMF Dial For All Attempts
5
3rd Telephone Number Enabled
3rd Telephone Number Disabled
6
Alternate Dial (1st & 3rd)
Call 1st Number, Back up to 3rd
7
For Future Use
8
Delinquency Follows Zone Activity (Hours)
Delinquency Follows Arming (Days)
Opt Def ON OFF
1
Open After Alarm Keypad Ringback Enabled
Open After Alarm Keypad Ringback Disabled
2
Open After Alarm Bell Ringback Enabled
Open After Alarm Bell Ringback Disabled
3
SIA Sends Programmed Reporting Codes
SIA Sends Automatic Reporting Codes
4
Closing Confirmation Enabled
Closing Confirmation Disabled
5
Talk/Listen on Phone Lines 1/3
No Talk/Listen on Phone Lines 1/3
6
Talk/Listen on Phone Line 2
No Talk/Listen on Phone Line 2
7
Contact ID Uses Programmed Reporting Codes
Contact ID Uses Automatic Reporting Codes
8
ULC Communications Priority Enabled
ULC Communications Priority Disabled/Standard Priority
Followed
Opt Def ON OFF
1
For Future Use
2
Alarm Communications Enabled During Walk Test*
Alarm Communications Disabled During Walk Test
3
Communication Cancelled Message Enabled
Communication Cancelled Message Disabled
4
Call Waiting Cancel Enabled*
Call Waiting Cancel Disabled
5
T-Link Interface Enabled
T-Link Interface Disabled
6
AC Failure Transmission Delay is in Hours
AC Failure Transmission Delay is in Minutes
7
Number of Dialing Attempt for Residential Dial is 1
Residential Dial Follows Dialing Attempts Counter
8
For Future Use
Opt Def ON OFF
1
Account Code Follows Phone Number
Account Code Follows Partition
2-8
For Future Use

Table of Contents