PowerSeries - PC1616/PC1832/PC1864
36
[101]-[164] Zone Attributes
Zone Attribute Defaults (Y = Option ON; N = Option OFF)
Attribute: 123456 7 8 9
ON
Audible Steady Chime Bypass Force* Swing Tx. Delay Wireless Zn Cross Zn
OFF
Silent Pulsed No No No No No No No
Zone Type:
00 Null Zone
NNNNNNN N N
01 Delay 1
YYYYNYN N N
02 Delay 2
YYYYNYN N N
03 Instant
YYYYNYN N N
04 Interior
YYNYNYN N N
05 Int. Stay/Away
YYNYYYN N N
06 Dly. Stay/Away
YYNYYYN N N
07 Dly. 24hr Fire (Hardw.)
YNNNNNN N N
08 Stand. 24hr Fire (Hardw.)
YNNNNNN N N
09 24hr Superv.
NYNNYNN N N
10 24hr Superv. Buzzer
NYNYNNN N N
11 24hr Burglary
YYNYNNN N N
12 24hr Holdup
NYNNNNN N N
13 24hr Gas
YNNNNNN N N
14 24hr Heating
YNNNNNN N N
15 24hr Auxiliary (Medical)
YYNNNNN N N
16 24hr Panic
YYNNNNN N N
17 24hr Emergency
YYNNNNN N N
18 24hr Sprinkler
YYNNNNN N N
19 24hr Water
YYNNNNN N N
20 24hr Freeze
YYNNNNN N N
21 24hr Latching Tamper
YYNNNNN N N
22 Momentary Keyswitch
NNNNYNN N N
23 Maintained Keyswitch
NNNNYNN N N
25 Interior/Delay
YYNYNYN N N
26 24hr Non-alarm
NNNNYNN N N
29 Auto Verified Fire
YNNNNNN N N
30 Fire Supervisory
NNNNNNN N N
31 Day Zone
YYNYYYY N N
32 Instant Stay/Away
YYNYNNN N N
35 24 hr Bell/Buzzer
YYNYNYN N N
36 24hr Non Latching Tamper
NYNNNYN N N
37 Night Zone
YYNYYYN N N
41 24hr Carbon Monoxide
YNNNNNN N N
81 24hr Carbon Monoxide (WLS)
YNNNNNN Y N
87 Dly. 24hr Fire (Wireless)
YNNNNNN Y N
88 Stand. 24hr Fire (Wireless)
YNNNNNN Y N
Attribute: 10 11 12 13 14 15 16
ON
Zone Attributes 10-13 For Future Use NC Loops SEOL DEOL
OFF
Config. Config. Config.
Zone Type:
00 Null Zone
NNNNNNN
01 Delay 1
NNNNNNN
02 Delay 2
NNNNNNN
03 Instant
NNNNNNN
04 Interior
NNNNNNN
05 Int. Stay/Away
NNNNNNN
06 Dly. Stay/Away
NNNNNNN
07 Dly. 24hr Fire (Hardw.)
NNNNNNN
08 Stand. 24hr Fire (Hardw.)
NNNNNNN
09 24hr Superv.
NNNNNNN
10 24hr Superv. Buzzer
NNNNNNN
11 24hr Burglary
NNNNNNN
12 24hr Holdup
NNNNNNN
13 24hr Gas
NNNNNNN
14 24hr Heating
NNNNNNN
15 24hr Medical
NNNNNNN
16 24hr Panic
NNNNNNN
17 24hr Emergency
NNNNNNN
18 24hr Sprinkler
NNNNNNN
19 24hr Water
NNNNNNN

Table of Contents