Chapter 4 Programming Descriptions
21
[378] Test Transmission Time
Program the time the system will report a Test Transmission reporting event. Program 4 digits – [HH][MM] using the twenty-four-hour sys-
tem. For a test transmission at 11:00 pm, program data [23][00]). Valid entries are [00][00] to [23][59]. Entering [99][99] will disable the test
transmission.
[379] Periodic DLS Time of Day
Programs the time the system will auto-call DLS. Program 4 digits – [HH][MM] using the twenty-four-hour system. For a DLS auto-call at
11:00 pm, program data [23][00]). Valid entries are [00][00] to [23][59]. Programming [99][99] will select a random time, [FF][FF] will dis-
able it.
[380] First Communicator Option Code
[381] Second Communicator Option Code
[382] Third Communicator Option Code
Delinquency Transmission Delay: Number of hours (Activity Delinquency) or days (Arming Delinquency) the panel will delay before transmit-
ting the event to the central station. Valid entries: [001] to [255].
Communication Cancel Window: Time, in minutes, after an alarm has occurred that the system will report a Communication Cancel reporting
event if the system is disarmed. They keypad will beep rapidly to indicate that the Communication Cancel reporting event has been communi-
cated successfully. Valid entries: [001] to [255]. Entering [000] will disable this window.
Option Description
[1]
ON:
the system communicator is enabled.
OFF: the communicator is disabled.
[2]
ON:
the system transmits alarm restorals if the zone is restored and the bell has timed out.
OFF: the system transmits alarm restorals immediately when the zone is restored.
[3]
ON:
the panel uses rotary (pulse) dialing. OFF: the panel uses DTMF (touchtone) dialing.
[4]
ON:
the panel will switch from DTMF dialing to rotary dialing after the 4th failed attempt to communicate.
OFF: the panel will use DTMF dialing for all dialing attempts.
[5]
ON:
the system uses the Third Phone Number to back up the First Phone Number.
OFF: the Third Phone Number is disabled.
[6]
ON:
the system alternates between the First Phone Number and Third Phone Number when attempting to report an event.
OFF: the panel will dial the First Phone Number for the programmed number of attempts, then switch to the Third Phone Number.
[7]
For Future Use
[8]
ON:
the Delinquency feature follows zone activity. OFF: the Delinquency feature follows arming.
Option Description
[1]
ON
: the keypad beeps 8 times after successfully transmitting the Opening After Alarm reporting event.
OFF: the keypad does not beep.
[2]
ON
: the bell output squawks 8 times after successfully transmitting the Opening After Alarm reporting event.
OFF: the bell output does not activate.
[3]
ON
: the system uses programmed reporting codes when transmitting using the SIA format.
OFF: the system automatically generates all reporting codes transmitted.
[4]
ON
: the system beeps the keypad 8 times after successfully transmitting a Closing reporting event.
OFF: the keypad does not beep.
[5]
ON
:
the system requests a Listen in/two-way session the next time it calls the 1st/3rd Phone Number when the PC59xx transmits a request
.
OFF: the system ignores the request from the PC59xx.
[6]
ON
: the system requests a Listen in/Two-way session the next time it calls the 2nd Phone Number when the PC59xx transmits a request.
OFF: the system will ignore the request from the PC59xx.
Options [5] and [6] are used with PC59xx series modules.
[7]
ON
: the system uses Contact ID format programmed reporting codes when transmitting reporting codes.
OFF: the system automatically generates all reporting codes transmitted.
[8]
ON
: the system will follow ULC Communication Priority.
OFF: the system will follow standard communications priority.
Option Description
[1]
For Future Use
[2]
ON
: the system will transmit all alarms during Walk Test. OFF: the system will not report alarm events during Walk Test.