[23] Fourth System Option Code
Refer to Programming Section [20] for programming instructions.
Zone Light 1 OFF = Partial Closings not identified
ON = Send Identified Partial Closings: manually bypassed or force armed zones (auto arming)
will be identified with their alarm transmissions between the partial closing code and the
closing code.
Zone Light 2 OFF = Auto-Arm does not send Partial Closing Code
ON = Auto-Arm sends Partial Closing Code: for zones that are manually bypassed or force
armed.
Zone Light 3 OFF = Any keypress cancels Auto-Arming
ON = Access code needed to cancel Auto-Arming
Zone Light 4 OFF = No access code needed to bypass zones
ON = Access code needed to bypass zones: use [Q][1][Access code] for zone bypassing
Zone Light 5 OFF = Master Access code can be programmed by the user
ON = Master Access code cannot be programmed by the user
Zone Light 6 OFF = One Time Use Code disable
ON = 16th code becomes One Time Use Code. The One Time Use Code may be used to arm
the system only once. After the code is used to arm the system, it will be automatically
erased and must be reprogrammed.
Zone Light 7 OFF = Quick exit disabled
ON = Quick exit enabled
Zone Light 8 OFF = Sensor Reset on Arming disabled
ON = Sensor Reset on Arming enabled. When Zone Light 8 is ON: the SW AUX output will reset
for 5 seconds when the system is armed. This function is used to reset latching smoke
detectors on the Fire Zone (Zone 7).
= Default setting
[24] Fifth System Option Code
Refer to Programming Section [20] for programming instructions.
Zone Light 1 OFF = Zones use Double End-of-Line zone loops
ON = Zones use Normally Closed zone loops
Zone Light 2 OFF = Zones follow setting of Section [24] Light 1
ON = Zonee use Single End-of-Line zone loops
Zone Light 3 OFF = Zones active on power-up
ON = Zones bypassed for 120s on power-up
Zone Light 4 OFF = No force arm for Auxiliary delay zones
ON = Force arm for Auxiliary delay zones
Zone Light 5 OFF = Home Away zones act as Interior zones when active
ON = Home Away zones act as Delay zones when active (see zone type 3 Section [18])
Zone Light 6 OFF = Bell is silent when keypad Panic [P] is activated
ON = Bell is audible when keypad Panic [P] is activated
Zone Light 7 OFF = Keypad is silent when keypad Panic [P] is activated
ON = Keypad emits 3 beeps when keypad Panic [P] is activated
Zone Light 8 OFF = Keypad Fire [F] key is enabled
ON = Keypad Fire [F] key is disabled
= Default setting