HOOK-UP DIAGRAM
BATTERY
12V 4.0Ah
GELL-CELL
MAX battery charge
current is 360 mA.
PC2550RK Keypad
Maximum: 5
Refer to the installation manual
for detailed instructions
on keypad wiring.
AUXILIARY
SUPPLY
OUTPUTS
400 mA
MAX
BELL/SIREN
700 mA MAX
NO
TO AUX TERMINAL
RJ31X
RED
BLK
Nut
Washer
Cabinet
Bolt
Ground
Rod
+12V
+12V
SWITCHED
-AUX
TRANSFORMER
16.5 VAC 40 VA
Incorrect connections may result in
blown fuses or improper operation.
Check wiring before applying power.
WARNING
DO NOT REPLACE
FUSES WITH HIGHER
VALUES THAN SHOWN
Do not connect transformer
to receptacle controlled
by a switch.
AC AUX+ AUX- SW
AUX
BELL
RED BLK YEL GRN
AUX-IN
Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8 PO1 PO2 PO3 PO4 A B C D
EGND
AUX
1AMP
BATT
5AMP
BELL
5AMP
+
_
RED
GRN
GRY
BRN
RED
BLK
YEL
GRN
EACHPOOUTPUT:
50mAMAXIMUM
TYPICAL ZONE CIRCUITS
DOUBLE EOL CIRCUIT
1 NORMALLY CLOSED CONTACT
1 NORMALLY OPEN CONTACT WITH
5600 EOL RESISTORS
ANY Z
TERMINAL
ANY COM
TERMINAL
ALARM
CONTACT
TAMPER
CONTACT
5600
5600
DOUBLE EOL CIRCUIT
1 NORMALLY CLOSED
CONTACT WITH 5600
END OF LINE RESISTORS
ANY Z
TERMINAL
ANY COM
TERMINAL
ALARM
CONTACT
5600
5600
DOUBLE EOL CIRCUIT
2 NORMALLY CLOSED CONTACTS
WITH 5600 EOL RESISTORS
ANY Z
TERMINAL
ANY COM
TERMINAL
ALARM
CONTACT
TAMPER
CONTACT
5600
5600
NORMALLY CLOSED
CONTACT;
NO END OF LINE
RESISTOR
ANY Z
TERMINAL
ANY COM
TERMINAL
END-OF-LINE RESISTOR ZONE
NORMALLY CLOSED DEVICES
ANY Z
TERMINAL
ANY COM
TERMINAL
NC
NC
5600
END-OF-LINE RESISTOR ZONE
NORMALLY OPEN AND
NORMALLY CLOSED DEVICES
ANY Z
TERMINAL
ANY COM
TERMINAL
NC
NO
5600
NC NO
YEL GRN
BLK RED
WHT
UTILITY
OUTPUT RELAY
Keypad [][7][1 or 2][Access Code]
COM
AUX+PO
RM-1
GROUND START
CIRCUIT
BLK RED
WHT
AUX+PO
A
GRN
RM-1
SMOKE DETECTOR CONNECTIONS
ALARM
CONTACT
IN
IN
OUT
OUT
ALARM
CONTACT
IN
IN
OUT
OUT
RED
WHT
BLK
GRN
POWER SUPERVISORY
RELAY (DSC RM-1)
5600 ohm
EOLR-2
ZONE 7 MUST BE
PROGRAMMED FOR FIRE
TO ZONE 7
TERMINAL
PROGRAMMED
FOR "FIRE"
TO ANY "COM"
TERMINAL
BELL LOOP
700 mA MAX
4-WIRE SMOKE
DETECTOR POWER
11.2 to 12.6 V
DC
300 mA
Smoke Detector must be latching type (such as ESL Model 445C).
To reset smoke detectors, press [
] then hold down [4] for 3 seconds.
All voltage outputs are rated 12VDC unregulated
Temperature Range: 0˚C-49˚C (32˚F-120˚F)
Maximum Humidity: 85% R.H.
NOTE: When more than 3 keypads
are connected, subtract 60mA
for each keypad in excess of 3
from the maximum AUX supply.