26
[25] Sixth System Option Code
Refer to Programming Section [20] for programming instructions.
Zone Light 1 • OFF = No Force Arming
ON = Force Arming on Zone Types 0, 1, 2 and 3. NOTE: If the system is armed and an exit is made
through a Delay Zone that may be force armed, the Home-Away zones will remain
automatically bypassed. To completely arm the system, enter an Access Code then [Q][1].
Leave the premises through any Delay Zone that may be force armed. The system will then
be completely armed at the end of the Exit Delay.
Zone Light 2 OFF = Standard Entry and Exit delay indications
• ON = Audible Urgency applied to Entry and Exit delay. See notes below.
Zone Light 3 • OFF = System will arm with either AC or DC present
ON = Power Loss Inhibits Arming: both AC and DC power
must must
must must
must
be present in order to arm system
Zone Light 4 • OFF = PC16OUT Module disabled
ON = PC16OUT Module on PO1 enabled (module provides 16 voltage outputs to indicate panel
conditions. See your distributor for details)
Zone Light 5 • OFF = 24Hr. Bell / Buzzer on Tamper: On a tamper condition the Bell will sound if system is armed
and the Buzzer will sound if the system is disarmed.
ON = 24Hr. Bell Always on Tamper: On a tamper condition the Bell will always sound.
Zone Light 6 • OFF = Tamper follows restore
ON = Installer Tamper reset: If a tamper condition occurs then Installer’s mode must be entered
([Q][8][Installers Code]) for the system to arm again.
Zone Light 7 • OFF = Zone 8 behaves as configured in Section [18]
ON = Zone 8 as an audible 24Hr.Tamper zone: When tripped, zone can only be reset by entering
Installer’s mode ([Q][8][Installers Code]), then initialized by arming the panel.
Zone Light 8 • OFF = Engineer Reset disabled
ON = Engineer Reset enabled: If an alarm occurs, the panel will not rearm until Installer’s mode
is entered.
All zones will behave as configured in Section [18] Zone Definitions.
Engineer Reset does not apply to the AUX INPUT zone.
• = Default setting
Entry and Exit Delay Urgency
When the urgency option is selected, the keypad will sound a steady tone during the Entry Delay and a pulsing tone
during the Exit Delay. During the last 10 seconds of the Entry Delay, the keypad will sound a pulsing tone to warn that
the Entry Delay is about to expire. During the last 10 seconds of the Exit Delay, the pulsing tone will quicken to warn
that the Exit Delay is about to expire. When the urgency option is not selected, the keypad will be silent for the Exit
Delay, and will sound a steady tone for the Entry Delay.