1.8 Viewing Trouble Conditions
The alarm control panel continuously monitors a number of possible
trouble conditions. If one of these conditions occurs, the keypad Trouble
light will turn on and a beeping sound will be heard every 10 seconds.
Press the [#] key to silence the keypad. The Trouble light will stay on until
the trouble is cleared.
To view which trouble conditions are present:
1. Enter [
*
] [2] at any keypad.
2. Use the arrow (< >) keys to scroll through the list of trouble
conditions:
If
AC TAC T
AC TAC T
AC T
rr
rr
r
oubleouble
oubleouble
ouble is present, the system has lost its power. This trouble may
be due to a power outage and should be cleared once the power is restored.
If the power on the premises is running normally and the trouble condition
persists, call your installer for service.
If
TLM TTLM T
TLM TTLM T
TLM T
rr
rr
r
oubleouble
oubleouble
ouble is present, there is a problem with the telephone line. If
the telephones on the premises are running normally and the trouble
condition persists, call your installer for service.
Any other trouble condition will require the assistance of your installer.
As soon as a trouble condition occurs, call your installer to have the
problem corrected as soon as possible.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PC4020 - V3.3 and is the answer not in the manual?

DSC PC4020 - V3.3 Specifications

General IconGeneral
Partitions8
Battery Backup12 VDC, 7 Ah
Power Supply16.5 VAC, 40VA
Outputs4 programmable outputs
CompatibilityCompatible with DSC PowerSeries keypads and accessories
Keypads SupportedPC5508, PC5508Z, PC5516, PC5516Z, PC5132, PC5132RKZ, PC5164, PC5164RKZ