Section 4: Access Control
Your installer will customize access levels 02-63 to suit your purposes.
Assigning access level 00 means that the user will never have access to
a given area. Assigning access level 01 means that the user will always
have access to a given area.
To program access level, perform the following. Your starting point
should be from the Program Code menu (from Step 3 above):
1. Use the right arrow (>) key to scroll to the following display:
Select (4) < >
Access Level
Press [
*
] or [4].
2. The display will read “Access Level Enter 00-63.” The numbers
“01”will be in the bottom right-hand corner of the display. This means
that the system has assigned Access Level 01 by default to the user
and the user will always have access. To assign another access level,
enter a 2-digit number from 00-63, corresponding to the new access
level.
3. Once the access level has been entered, press [#]. The display will
return to “Select (4) Access Level.”
User Options
Once the access level has been programmed, three different user
options must be programmed. These options are the following:
CarCar
CarCar
Car
d Vd V
d Vd V
d V
alidalid
alidalid
alid: This option allows the user’s access card to become active
on the system. Make sure the access card number is also programmed.
Prvleged CarPrvleged Car
Prvleged CarPrvleged Car
Prvleged Car
dd
dd
d: A privilege card user will be able to access areas via an
access card entry point when general access is prohibited. This option,
when enabled, will also give the user the ability to grant access to users
who have a “Wait for Privilege” access card (see next option).
WW
WW
W
ait for Prvlait for Prvl
ait for Prvlait for Prvl
ait for Prvl: This option will restrict the user’s access to areas via an
access card entry point when access is prohibited. A Wait for Privilege
user, however, can gain access to the system under the following
condition: A Privilege cardholder must present their card after the Wait
for Privilege user swipes theirs.
Table 2-1 shows which codes have these options turned on by default.
To change the user option settings for these features, follow the
directions outlined in Section 2.3 “Change User Code Options.”

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PC4020 - V3.3 and is the answer not in the manual?

DSC PC4020 - V3.3 Specifications

General IconGeneral
Partitions8
Battery Backup12 VDC, 7 Ah
Power Supply16.5 VAC, 40VA
Outputs4 programmable outputs
CompatibilityCompatible with DSC PowerSeries keypads and accessories
Keypads SupportedPC5508, PC5508Z, PC5516, PC5516Z, PC5132, PC5132RKZ, PC5164, PC5164RKZ

Related product manuals