6
HSPA(3G) Alarm Communicator Installation Manual
TL2803G(R) (Ethernet/Internet + HSPA(3G)/GPRS dual-path)
Features
128-bit AES encryption via cellular and Ethernet/Internet (NIST validation certificate number
2645).
Back up or primary cellular alarm communication.
Automatically switches to 2G (EDGE/GPRS) if HSPA(3G) service is not available.
Ethernet LAN/WAN 10/100 BASE-T (TL2803G(R) only).
Fully redundant Ethernet/Internet and cellular dual-path alarm communication (TL2803G(R)
only).
Full event reporting to central station.
Individual Internet and/or cellular periodic test transmission.
Integrated call routing.
Visual Verification (Requires Sur-Gard System 5 Receiver)
Remote firmware upgrade capability of the communicator and panel firmware via Ethernet and/
or cellular.
Panel remote uploading/downloading support via cellular and Ethernet/Internet.
PC-LINK connection.
Programmable labels.
SIA and Contact ID (CID) formats supported.
Signal strength and trouble display LEDs.
Supervision heartbeats sent via cellular and Ethernet/Internet.
Technical Specifications
The TL2803G(R) is also suitable to be used with a compatible control unit listed for dual line
security transmission when used in conjunction with a DACT or a Public Switched Data Net-
work (PSDN) transmitter, where the PSDN provides the line security and is the primary line. In
this mode, alarm signals are required to be sent simultaneously over both communication meth-
ods.
EN50131-1 Installation Requirements
For EN50131-1 compliant installations, the following programming options shall be set as
described.
Supervision Heartbeat (required for ATS4 and ATS5):
[851][004] set to 0087h (135s heartbeat).
NOTE: The compatible receiver at ARC location shall have supervision window programmed for
1800s (ATS4) or 180s (ATS5).
[851][005] options 1,2 and 3 shall be enabled
[851][005] option 8 shall be enabled
Test transmission (required for ATS3):
[851]
System test options
[026-029]
shall be enabled (FF) for the communication paths available.
[851][124-125] and [224-225] shall be programmed with time of day for test transmission and
1440 minutes (24h) for test transmission cycle
Configuration of communication paths (all ATS classes)
[300][001] select option 02 for auto routing (this will allow transmission of the events over all
available communication paths in the system)
[380] enable option 5 (YES) for parallel transmission over all available communication paths
(if redundant configuration is desired)
[382] enable option 5 (YES) this will enable Alternate communicator
[384] enable the desired back-up configuration (receiver 2 back-up for receiver 1 or receiver 3
back-up for receiver 1).