HSPA(3G) Alarm Communicator Installation Manual
Ratings Compatibility
NOTE: Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Encryption
The communicator uses 128 Bit AES encryption. Encryption can only be enabled from the moni-
toring station receiver. Each receiver (Ethernet 1 and 2, cellular 1 and 2) can independently have
encryption enabled or disabled. When encryption is enabled, the central station will configure the
device to encrypt communications the next time the communicator module performs a communi-
cation to that receiver.
NOTE: Packets will start being encrypted only after the next event is sent to that receiver, or if the
unit is restarted.
Before leaving the installation site, the communicator TL2803G(R) Ethernet line shall be con-
nected via an APPROVED (acceptable to the local authorities) Network Interface Device (NID).
All wiring shall be performed according to the local electrical codes.
This Internet and HSPA(3G) dual-path alarm communicator shall be installed by service persons
only (service person is defined as a person having the appropriate technical training and experi-
ence necessary to be aware of hazards to which that person may be exposed to in performing a task
and can also take measures to minimize the risks to that person or other persons). The Communi-
cator shall be installed and used within an environment that provides the pollution degree max 2,
overvoltages category II, in non-hazardous, indoor locations only. This manual shall be used with
the installation manual of the panel which is connected to the communicator. All instructions spec-
ified within the panel manual must be observed.
Table 1: Communicator Ratings
Model
3G2080(R)
Cellular only
TL2803G(R)
Internet and Cellular
Power Supply Ratings
Input Voltage
10.8-12.5 VDC
Power is supplied from the panel’s PC-Link header or a PCL-422 module in
remote cabinet installations. In remote cabinet installations, the PCL-422 module
located with the communicator is powered by either an HSM2204 or an
HSM2300. Refer to the PCL-422 installation instructions for details.
Current Consumption
Standby Current 90mA @ 13.66V 120mA @ 13.66V
Alarm (Transmitting) Current 400mA @ 12V
Operating Frequency 900MHz, 1800MHz, 2100MHz
Typical Antenna Gain 2dBi
Environmental Specifications
Operating Temperature -10°C to 55°C
Humidity 5% ~ 93% relative humidity, non-condensing
Mechanical Specifications
Board Dimensions (mm) 100 × 150 × 15 100 × 150 × 15
Weight (grams) with bracket 310 320
Table 2: Compatible Receivers and Panels
Communicator
Receiver/
Panel
Description
3G2080(R)
TL2803G(R)
Receiver
Sur-Gard System I Receiver, version 1.13+
Sur-Gard System II Receiver, version 2.10+
Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver
Panel
HS2016
HS2032
HS2064
HS2128
PRE INSTALLATION CONFIGURATION