SECTION 8 | ALARM MESSAGES
403-618-03 Infinity™ Series Servo Ultrasonic Press Systems User Manual
84



hps://support.dukane.com/EasyAlarm
Alarm Code Alarm Message Explanation Solution
U100

Default Setup corrupted, Model Number in-
correct, Serial Number incorrect, Feedback
Scaling incorrect, etc.

Dukane.
U101

Internal generator fault. Contact Dukane.
U102

Internal generator fault. Contact Dukane.
U103




Dukane.
U104
Frequency Overload Fault

The generator did not obtain a frequency
lock by the end of ramp up period.






maintenance.
-
dure.

and re-inspect.


from a test.



occurrences for a properly maintained stack.
If the above steps do not resolve problem, contact
Dukane.
U106
Peak Overload Fault 

the ultrasound output.

Check if one of the stack components is loose.

are set correctly.
U108
Average Overload Fault

and has terminated
the ultrasound output.



U110   Verify that the incoming AC Line voltage supplied to the

Consult the manual for your generator
U111 Overtemperature Fault 
limit.
Check for blockage of air vents on the sides of the gen-


Alarm Messages