Soft Serve Freezer Model GES-102
184559 67
Error Code Description/Action Probable Cause Remedy
SHORT Displays SHORT when
a thermistor has failed in
a shorted state.
Action: Affected System
is cycled off.
Reset Method: Auto
once issue is corrected.
1. Faulty wire
connection
2. Faulty Thermistor
1. Check to ensure wires have not
rubbed through and shorted out
together or the wire harness is not
resting in water.
2. Change thermistor
OPEN Displays OPEN when a
thermistor has failed in
an open state.
Action: Affected system
is cycled off
Reset method: Auto
once issue is corrected
1. Faulty wire
connection
2. Faulty Thermistor
1. Check to ensure Molex connectors
are connected fully and that no wiring
from the control board to the sensor
has been severed.
2. Change Thermistor
CYL. T
ALARM
Displays CYL T ALARM
when the cylinder
temperature has
reached 36 degrees for
over 2 minutes.
Action: Alarm is
displayed only and will
not change the state of
the machine.
Reset Method: The
main power switch must
be cycled to reset error.
Please refer to the
error CYL RFG for
troubleshooting.
Please refer to the error CYL RFG for
troubleshooting.
CAB T
ALARM
Displays CAB T ALARM
when the cabinet
temperature has
exceeded 41 degrees
for 15 minutes.
Action: Alarm is
displayed only and will
not change the state of
the machine.
Reset Method: The
main power switch must
be cycled to reset error.
Please refer to the
error CAB RFG for
troubleshooting.
Please refer to the error CAB RFG for
troubleshooting
15 VQM Error Codes (continued)