You may avoid inconvenience and service calls by checking these points before you call for service.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
1. Do Not try to light any appliance.
2. Do not touch any electric switch, do not use the phone.
3. Leave the building immediately, then call your gas supplier.
4. Ifyou cannot reach the gas supplier, call the fire department.
Possible Cause
Thermostatisnot set correctly
Burner is not operating properly
No electric powerto boiler
Controls out ofadjustment
Radiators not heating
Poor electrical contact
Rollout switch blown
Chimney flue is blocked
Vent damper not operating
Possible Cause
Gas input amount isincorrect
Possible Cause
Notenough ventilation
Chimney flue is blocked
Possible Cause
Air insystem
What to do
Resetthermostat above room temperature.
Check flame. If it is yellow, the burner is not getting enough air. Or, if flame
is blue and noisy and seems to lift off the burner, the burner is getting too
much air.Contact your service technician.
Check overcurrent protection. Check to be sure electric power supply circuit
is "ON."
Resetaccording to instructions.
Steam air vents are not operating properly Check flow control valve (if used).
It may be in closed position.
Check all control terminals and wire joints.
Haveyour servicetechnician check heat exchanger for blockage. Replacerollout
switch with exact replacement.
Spill switch contacts open, requiring manual reset of spill switch. Have your
service technician check and correct chimney problem.
Consulttroubleshooting guide in Effikal manual, packaged with vent damper.
What to do
Contact your service technician.
What to do
Contact your service technician.
Haveyour service technician check and correct, if necessary
What to do
Refer to "Radiators Not Heating Properly" above
HAVE YOUR SERVICE TECHNICIAN CHECK ANY PROBLEM YOU ARE UNABLE TO CORRECT.