Page #39 background imageLoading...
Page #39 background image
Connecting
to
an External Battery
To
connect the Duracell® Powerpack to an external
battery using the
jump-start
cables:
1.
Ensure that the jump-start power switch is OFF.
2. Connect the red positive (+) clamp
of
the cables to the
red positive (+) terminal
of
the external battery.
3.
Connect the black negative
(-)
clamp
of
the cables to the
black negative
(-)
terminal
of
the external battery.
If
the Red Jumpstart Connection LED illuminates and the
alarm sounds, then reverse polarity has been detected.
Correct polarity must be established before proceeding.
Disconnect the jump-start clamps from the battery and
redo steps 2 and 3 in this procedure.
If
no alarm sounds, and the Green Jumpstart Connection
LED is illuminated, then proceed to the next step.
4. Switch
ON the jump-start power switch.
To
disconnect the cables from an external battery and
from the Duracell® Powerpack:
1.
Ensure that the jump-start power switch is OFF.
2. Remove the red positive (+) clamp, and then remove the
black negative
(-)
clamp from the external battery
terminals.
3. Store the jump-start clamps in the appropriate holder on
each side
of
the Duracell® Powerpack.
4. Recharge the Duracell® Powerpack as soon as possible
after use.
If'
CAUTION
~
Do not recharge the Duracell® Powerpack when an external battery
is connected. The AC charger may be damaged.