Assembling the remaining thread monitor
Additional Instructions 867/867-M PREMIUM - 00.0 - 07/2018 11
Fig. 7: Connecting the remaining thread monitor on PREMIUM machines (2)
3. Insert the magnet valve (2) into socket X16 on the circuit board (1).
If socket X16 is already occupied, use socket X17 or socket X18.
4. Assemble the circuit board (1).
5. Tighten the connection plate (4) on the holder (3).
Fig. 8: Connecting the remaining thread monitor on PREMIUM machines (3)
(1) - Circuit board
(2) - Magnet valve
(3) - Holder
(4) - Connection plate
(5) - Compressed air maintenance unit
(6) - Hose
(7) - Valve