PAGE - 5
Key
Parameters Function Range Pre.setting Description
HVP -20 Parameters List for DA-251 (MAC. 35)
Parameters
Code
ON : No foot lifting at heeling pedal.
OFF : Has foot lifting at heeling pedal.
ON : No function at heeling pedal. ( foot lifter and need up function are also invalid)
OFF : Trimmer is functioned at heeling pedal.
When the pedal is returned to neutral position, trimming works automatically.
O N : Enable. Only valid when 072.FHC= OFF
OFFDisable.
Foot lifter output signal converted.
ON : The foot lifter goes up during sewing.
OFF: Function invalid.
Trimming device protection for Cover-Stitch machine.
NCNormal close. When signal at open , motor immediately stops and rotation symbol will stop.
NONormal open. When signal at close , motor immediately stops and rotation symbol will stop.
With TCL trigger signal input, the next trimming will be cancelled as full heeling the pedal.
ONValid.
OFFInvalid.
Canceling the interlock timer for quick restarting. For machine without trimmer device only.
ONValid.
OFFInvalid.
Motor running mode at trimming sequence selection.
LKFor general Lock-Stitch machines .Trimming from needle down to up.
RKFor Chain-Stitch machine easy pull out cycle. Needle stops with a reverse angle set by 116.DRU.
KAFor general Cover-Stitch machines with under trimmer only.
KBFor special Cover-Stitch machines with upper trimmer .
KCValid only when 079. LTM=TK and 081. TS】>0, otherwise function same as LK mode.
Reference the timing chart.
T1At down position delayed 081. TS angles on, at up position delayed 083. T2 time off.
T2At down position delayed 081. TS angles on, extended 084. TE angles off.
T3At down position delayed 081. TS angles on, extended 083. T2time off.
T4At down position delayed 082. T1 time on, extended 083. T2 time off.
TKAt up position delayed 082. T1 time on, extended 083. T2 time off.
TSAt down position always on, at up position delayed 082. T1 time on, extended 083. T2 time.
T7At down position delayed 081. TSangles on, at up position off, and delayed 082. T1time on,
extended083. T2time off.
Reference the timing chart.
L1At down position delayed 085. LS angles on, at up position delayed 087. L2time off.
L2At down position delayed 085. LSangles on, extended 088. LEangles off.
L3At down position delayed 085. LS angles on, extended 087. L2time off.
L4At down position delayed 086. L1 time on, extended 087. L2 time off.
LKAt up position delayed 086. L1 time on, extended 087. L2 time off.
LSAt down position always on, at up position delayed 086. L1 time on, extended 087. L2 time off.
L7At down position delayed 085. LS angles on, at up position off, and delayed 086. L1 time on,
extended087. L2 time off.
81
TS Delayed angles prior to trimmer engaged 0 - 360 degrees 0
Valid for079. LTM= T1/T2/T3/T7 .
82 T1 Delayed timing prior to trimmer engaged 0 - 990 ms 0
Valid for079. LTM= T4/TK/TS/T7.
83 T2 Trimming time 0 - 990 ms 20
Valid for079. LTM= T1/T3/T4/TK/TS/T7.
84 TE Setting angles of trimming 0 - 360 degrees 0
Valid for079. LTM = T2 .
85 LS Delayed angles prior to tension release engaged 0 - 360 degrees 0
Valid for 080. LLM = L1/L2/L3/L7 .
86 L1 Delayed timing prior to tension release engaged 0 - 990 ms 0
Valid for080. LLM= L4/LK/LS/L7.
87 L2 Timing of tension release 0 - 1500 ms 30
Valid for080. LLM = L1/L3/L4/LK/LS/L7.
88 LE Setting angles of tension release 0 - 360 degrees 0
Valid for080. LLM= L2 .
P
O
W
E
R
..
O
N
OFFON/OFFTrimming works at neutral pedal
ON/OFF OFF
OFFCancel trimming at full-heeling pedal ON/OFF
Cancel foot lifting at full- heeling pedal
OFF
75 SFM Safety switch protection mode NC/NO NO
Converter for foot lifter signal output74 FRV ON/OFF
OFF
77 ILC Cancel of interlock timing after full heeling pedal ON/OFF OFF
76 TCL Thread trimmer cancel ON/OFF
L1/L2/L3/L4/LK/LS/L7
LK
79 LTM
Mode selection for trimming sequence.
( For TM output signal )
T1/T2/T3/T4/TK/TS/T7 TS
LK/RK/KA/KB/KC
LS
78 TRM Motor running mode at trimming sequence
72 FHC
71 FL
73 NTC
80 LLM
Mode selection for tension-release sequence.
For ML output signal
From the library of: Diamond Needle Corp