PAGE - 7
Key
Parameters Function Range Pre.setting Description
HVP -20 Parameters List for DA-251 (MAC. 35)
Parameters
Code
W : Regular wiper function (active 1 time when full heeling back after sewing)
O : Wiper works at each full heeling back (unlimited )
A : Wiper works only the pedal is kept full heeling back . Wiper turn off when the pedal return to neutral.
Note : Wiper on time controlled by the 093. W2.
113 DEG Needle DOWN position stop angle 5 - 180 degrees 12 Adjust the needle down stop position.
114 UEG Needle UP position stop angle 5 - 180 degrees 12 Adjust the needle up stop position.
Power on display condition selection.
ONWhen power switch turned on, the panel displays previous condition. (Keep previous condition).
OFFWhen power switch turned on, the panel displays normal mode.
116 DRU Reverse angles through Needle down and up 1 - 360 degrees 180
Valid only when 078. TRM=RKmode
Motor reverses from needle down, and stops at the needle upper dead point.
117 ER Error code display
10 SETS
- Error code history display , total 10 events can be memorized.
ONWithout the synchronizer , motor is running as a clutch motor and stops at random position.
OFFWith synchronizer .
ONDirect drive.
OFFBelt drive.
120 FHM
Mode selection for full-heeling after power on
or trimming
FU/NU/NO/NUF/EFF FU
F U : Regular operation -- full heeling for trimming and foot lifting.
N U : Full heeling for up needle.
N O : No foot lifting function.
NUF : Full heeling for foot lifting and up needle.
EFF : Full heeling for foot lifting and running at low speed.
121 ANU Needle goes up as power turned ON ON/OFF OFF
O N : Automatic needle UP at power on.
OFF : Function invalid.
122 HL Upper limit of maximum speed 50 - 9999 spm 4500 The motor's maximum speed setting.
P
O
W
E
R
..
O
N
W/O/A W
OFF
118 NOS Converting to a clutch motor selection ON/OFF OFF
115 PMD Power on display condition ON/OFF
OFF119 DD Direct drive or belt drive ON/OFF
Wiper function related to full-heeling pedal112 WMD