EasyManuals Logo

Dynamic RHINO2 DS120 User Manual

Dynamic RHINO2 DS120
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
6.5.9.3 Slows to
The Slows to parameter sets the speed to which the controller slows down when a Slow
function is active.
If set to 0%, the controller will decelerate at the programmedEmergency Deceleration rate
and apply the park brake.
If set to 100%, the Slow function will have no effect.
Any values between 0% and 100% will cause the controller to decelerate using the
programmed forward or reverse deceleration rate.
6.5.9.4 Latches
The Latches parameter sets whether the function will become latched once active. If a
function is latched, the active condition will have to be removed and the controller turned
off and then on again before the function will be turned off.
The Latches parameter only applies to those functions that inhibit driving: Charger Inhibit
and Stop.
Note
If 'Latches' is selected, please select 'Flashes' as well to indicate to the user why the scooter will not drive.
6.5.9.5 Flashes
The Flashes parameter sets whether during a Drive Inhibit condition (when a Stop function
is active or a Charger Inhibit condition occurs) a flash code will be displayed. The flash code
that is displayed depends on the setting of the Flash Code Type parameter. See also
section7.2 Flash Code Display.
GBK51948 RHINO2
Installation Manual Issue 5
Programming - Page 117

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic RHINO2 DS120 and is the answer not in the manual?

Dynamic RHINO2 DS120 Specifications

General IconGeneral
BrandDynamic
ModelRHINO2 DS120
CategoryController
LanguageEnglish

Related product manuals