26-Installation
Note: Afterthewholesystemconnection,setthemasterDIPmodeaccordingtothe
invertermodelrstly,thenstartthebattery.
Note: Formoreinformationofmatchinginverterbrands,pleasesubjecttothelatest
document.
Eachpairofpowercable,it’slimitedcontinuouscurrentis120A,soiftheinverter
Max.workcurrentmorethan120A,pleaseaddpowercableaccordingtothe
proportion.
3.7.4 Batteryparametersettingsontheinverter
MaxCharging(Bulk)Voltage:53.5V
AbsorptionVoltage:53V
FloatVoltage:52.5V
ShutDown(cutoff)Voltage:47V
ShutDown(cutoff)SOC:20%
RestartVoltage:49V
MaxChargeCurrent:25A*batteryQTY
MaxDischargeCurrent:25A*batteryQTY
Capacity:1*B4850=50Ah
3.7.5 Registeronthewebsiteafterinstallation
Afterthebatterysysteminstallationiscompletedandtherunningisnormal,you
needtologintotheDYNESSofcialwebsitetoregistertheproductinstallationand
useinformationtomaketheproductwarrantyeffective.
Pleasefollowtheinstructionsonthewebsitetoregister.
dyness-tech.com->Service->Sign.