45
Guidance and manufacturer’s declaration – electromagnetic emissions
This device is intended for use in the electromagnetic environment specied below. The customer or the user of this device should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment – guidance
RF emissionsCISPR 11 Group 1 This device uses RF energy only for its internal function. Therefore, its RF emissions are very low and are
not likely to cause any interference in nearby electronic equipment.
RF emissionsCISPR 11 Class B This device is suitable for use in all establishments, including domestic establishments and those directly
connected to the public low-voltage power supply network that supplies buildings used for domestic
purposes.
Harmonic emissionsIEC 61000-3-2 Not applicable
Voltage uctuations/icker emissionsIEC 61000-3-3 Not applicable
Guidance and manufacturer’s declaration – electromagnetic immunity
This device is intended for use in the electromagnetic environment specied below. The customer or the user of this device should assure that it is used in such an environment.
Immunity test IEC 60601test level Compliance level Electromagnetic environment –guidance
Electrostatic discharge (ESD)
IEC 61000-4-2
±6 kV contact
±8 kV air
±6 kV contact
±8 kV air
Floors should be wood, concrete or ceramic tile. If oors are covered with
synthetic material, the relative humidity should be at least 30 %.
Power frequency (50/60 Hz)
magnetic eld
IEC 61000-4-8
3 A/m 3 A/m
Power frequency magnetic elds should be at levels characteristic of a typical
location in a typical commercial or hospital environment.
NOTE UT is the a.c. mains voltage prior to application of the test level.