33..55..22 PPoowweerr MMaannaaggeemmeenntt SSooffttwwaarree
Intelligent Power software products offer tools for monitoring and managing power devices across the
network. See Section
6.1 About communication interfaces for more information.
33..55..33 AAuuttoommaattiicc UUPPMM FFWW uuppddaattee
The UPS automatically updates the firmware of the UPM plugged in a live system. The UPM FW will be
updated to the same version that all the other UPMs in the UPS use.
33..55..44 AAuuttoommaattiicc UUPPSS oouuttppuutt ppoowweerr ccoonnffiigguurraattiioonn
The UPS automatically calculates the output power capacity based on the number of UPMs connected to
the device.
33..66 OOppttiioonnss aanndd aacccceessssoorriieess
Contact your Eaton sales representative for more information about the available options and
accessories.
33..66..11 MMaaiinntteennaannccee BByyppaassss SSwwiittcchh
The Maintenance Bypass Switch (MBS) enables power to completely bypass and isolate the UPS so that
the UPS can be safely serviced without interrupting power to critical systems.
The MBS is available internally as an option for 200 kW/240 kVA frames or in an external enclosure as an
accessory item.
33..66..22 TToopp aaiirr eexxhhaauusstt kkiitt
The top air exhaust kit is used to direct the UPS cooling air front-to-top. The kit will eliminate the cooling
clearance requirement from the back of the unit, and enable installing the UPS even against a wall, in a
corner or back-to-back.
Refer to Section
4.4 Site preparations for further information.
33..66..33 SSiinnggllee ffeeeedd kkiitt
The Eaton 93PM G2 UPS is configured for dual feed by standard, requiring a separate feed for rectifier
and static bypass input. Single feed kit is available both as factory installed or on-site installed option.
33..66..44 IInntteerrnnaall bbaatttteerryy bbrreeaakkeerr
The internal battery breaker disconnects the DC supply to the UPS so that the UPS can be safely
serviced.
33..77 UUPPMM iinnssttaallllaattiioonn aanndd rreeppllaacceemmeenntt
A new UPM can be installed in the cabinet any time in the future when power needs change. This enables
the UPS system to grow with the business, thus lowering the initial investment required for the system on
day one.
For a listing of the upgradeable configurations, see Table
2: UPS configurations.
EATON 93PM G2 UPS USER’S AND INSTALLATION GUIDE P-164000956
-
February 2021 www.eaton.eu 2277

Table of Contents

Related product manuals