User Manual MN04200002E
Effective January 2016
C441 Ethernet module user manual
(C441R, C441T, C441U, C441V)
EATON www.eaton.com
Table 84. Class 41 (0x29): Control Supervisor Object (Cont.)
Attrib NV Access
Data
Type Name Description
123 (0x7B) NV Set/Get USINT Fault Reset
Mode
Fault reset mode
0x00 - manual reset
0x01 - auto reset
0x02 - power on reset (reset
faults on power cycle)
124 (0x7C) NV Set/Get UINT Auto Reset
Delay Time
Delay time after fault before
attempting to auto reset
125 (0x7D) NV Set/Get UINT Auto Reset
Attempt Limit
Max number of auto reset
attempts; once reached,
S811 requires manual reset
to clear fault
126 (0x7E) NV Set/Get USINT Motor Comm
Loss Action
Motor comloss action
0x00 - auto stop
0x01 - auto run1
0x02 - unavailable
0x03 - hold last state
0x04 - unavailable
0x05 - unavailable
0x06 - unavailable
0x07 - all stop fault (will trip
S811+ and issue all stop
fault)
127 (0x7F) NV Set/Get UINT Transient Motor
Control Timeout
Motor control timeout for
transient UI devices
128 (0x80) NV Set/Get UINT Motor Control
Command
Timeout
Motor control timeout - com-
munication idle time which
will cause a Motor Control
Device Missing fault
129 (0x81) V Set/Get USINT Modbus Device
Reset Register
Register performs reset ser-
vices on S811+ over modbus
0x00 - no reset
0x01 - soft reset (power
cycle reset)
0x02 - factory reset (reset
device back to defaults)
0x03 - app parameter reset
0x04 - reserved
0x05 - reserved
0x06 - flush fault queue/list
130 (0x82) NV Set/Get BOOL Alarm - No Trip
Enabled
Alarm no trip enable allows
the S811+ to continue to run
through any motor faults.
Fault will be issued but will
not stop the starter. Faults
meant to protect the soft-
starter will continue to trip
the starter
131 (0x83) NV Set/Get UINT EtherNet/IP
Comm Timeout
Range: 0–60,000 ms
Default: 3000 ms
Table 85. Class 44 (0x2C): Overload Object
Instance Count: 1
Instance List: 1
Attrib NV Access
Data
Type Name Description
4
(0x04)
NV Set/Get USINT Overload Trip
Class
Overload Trip Class ( 5 - 30; 20
default)
7
(0x07)
V Get USINT % Thermal
Pile used
Thermal Pile Used Percentage - Trip
at 100%
100
(0x64)
V Set/Get UINT Motor
Nameplate
FLA in 0.1A
Full load amperage rating of motor
scaled in 0.1A (deci Amps)
101
(0x65)
V Get UINT 3Ph Ave
Line Current
(deciamps)
Scaled RMS average of the 3phase
line current - This is the actual cur-
rent flowing to the motor in 0.1A.
102
(0x66)
V Get UINT 3Ph RMS
Line Current
(deciamps)
Scaled RMS 3phase line current -
This is the actual current flowing to
the motor in 0.1A (L1).
103
(0x67)
V Get UINT 3Ph RMS
Line Current
(deciamps)
Scaled RMS 3phase line current -
This is the actual current flowing to
the motor in 0.1A (L2).
104
(0x68)
V Get UINT 3Ph RMS
Line Current
(deciamps)
Scaled RMS 3phase line current -
This is the actual current flowing to
the motor in 0.1A (L3).
105
(0x69)
V Get UINT Average
current as %
FLA
Average of the 3 phase current as a
percentage of the Motor Nameplate
fla setting
106
(0x6A)
V Get UINT 3Ph Ave
Line Current
(amps)
Scaled RMS average of the 3phase
line current - This is the actual cur-
rent flowing to the motor in 1.0A.
107
(0x6B)
V Get UINT 3Ph RMS
Line Current
(amps)
Scaled RMS 3phase line current -
This is the actual current flowing to
the motor in 1.0A (L1).
108
(0x6C)
V Get UINT 3Ph RMS
Line Current
(amps)
Scaled RMS 3phase line current -
This is the actual current flowing to
the motor in 1.0A (L2).
109
(0x6D)
V Get UINT 3Ph RMS
Line Current
(amps)
Scaled RMS 3phase line current -
This is the actual current flowing to
the motor in 1.0A (L3).
110
(0x6E)
V Get UINT Ave 3Ph
Real Power
(kW)
Average 3phase real power (in kW)
111
(0x6F)
V Get INT Power Factor Power factor reading 0 - 1.0000 (in
0.0001)
112
(0x70)
NV Set/Get USINT Overload Trip
Enable
Motor overload trip enable
0x00 - disable
0x01 - fault enable
0x02 - warning enable
113
(0x71)
V Set/Get BOOL Enable
Overload
During Start
Enable the overload during start
ramp
0x00 - overload is disabled during
start ramp
0x01 - overload is enabled during
start ramp
114
(0x72)
NV Set/Get USINT Undercurrent
Trip Enable
Low load current trip enable
0x00 - disable
0x01 - fault enable
0x02 - warning enable
115
(0x73)
NV Set/Get USINT Undercurrent
Trip Level (%
FLA)
Low load current trip threshold in
percent of the motor nameplate fla
setting
116
(0x74)
NV Set/Get UINT Undercurrent
Trip Duration
Amount of time a low current condi-
tion must exist before a trip; 0.0
- 60.0 (in 0.1secs)
117
(0x75)
NV Set/Get USINT Motor Jam
Trip Enable
Motor jam trip enable
0x00 - disable
0x01 - fault enable
0x02 - warning enable
118
(0x76)
NV Set/Get USINT Motor Stall
Trip Enable
Motor stall trip enable
0x00 - disable
0x01 - fault enable
0x02 - warning enable