9
Signal Input
DIP Switch Position 1
12 VDC Out
1
2
3
4
+
ONDIP Switch Position 3
OFF
X
Rate Signal In
Program Enable In
Ground
Rate Input DIP Switch Settings
Position ON OFF
1
2
3
Sink (NPN)
200 Hz Max.
Mag Pickup
Source (PNP)
10 kHz Max.
Single Ended
12 VDC Out @ 75 mA Max.
See Specifications (pages 17-18) for input impedances and threshholds.
Relay Output Option Board
Typical Wiring
Durant
®
1
Terminal Designation
Relay
2
Relay
1
External
Power
6
5
4
3
2
1
Load
1
6
5
4
3
2
1
1
An RC surge suppressor is recommended across all inductive loads.
Contact Ratings
5 A @250 VAC or 30 VDC maximum