Name Description
Logic.LE78.Gate In3-I State of the module input: Assignment of the Input Signal
Logic.LE78.Gate In4-I State of the module input: Assignment of the Input Signal
Logic.LE78.Reset Latch-I State of the module input: Reset Signal for the Latching
Logic.LE79.Gate Out Signal: Output of the logic gate
Logic.LE79.Timer Out Signal: Timer Output
Logic.LE79.Out Signal: Latched Output (Q)
Logic.LE79.Out inverted Signal: Negated Latched Output (Q NOT)
Logic.LE79.Gate In1-I State of the module input: Assignment of the Input Signal
Logic.LE79.Gate In2-I State of the module input: Assignment of the Input Signal
Logic.LE79.Gate In3-I State of the module input: Assignment of the Input Signal
Logic.LE79.Gate In4-I State of the module input: Assignment of the Input Signal
Logic.LE79.Reset Latch-I State of the module input: Reset Signal for the Latching
Logic.LE80.Gate Out Signal: Output of the logic gate
Logic.LE80.Timer Out Signal: Timer Output
Logic.LE80.Out Signal: Latched Output (Q)
Logic.LE80.Out inverted Signal: Negated Latched Output (Q NOT)
Logic.LE80.Gate In1-I State of the module input: Assignment of the Input Signal
Logic.LE80.Gate In2-I State of the module input: Assignment of the Input Signal
Logic.LE80.Gate In3-I State of the module input: Assignment of the Input Signal
Logic.LE80.Gate In4-I State of the module input: Assignment of the Input Signal
Logic.LE80.Reset Latch-I State of the module input: Reset Signal for the Latching
Sgen.Running Signal: Measuring value simulation is running
Sgen.Ex Start Simulation-I State of the module input:External Start of Fault Simulation (Using the test parameters)
Sgen.ExBlo Module Input State: External Blocking
Sgen.Ex ForcePost-I State of the module input:Force Post state. Abort simulation.
Sys.PS 1 Signal: Parameter Set 1
Sys.PS 2 Signal: Parameter Set 2
Sys.PS 3 Signal: Parameter Set 3
Sys.PS 4 Signal: Parameter Set 4
Sys.PSS manual Signal: Manual switch over of a Parameter Set
Sys.PSS via Comm Signal: Parameter Set Switch via Communication
Sys.PSS via Inp fct Signal: Parameter Set Switch via Input Function
Sys.Min. 1 param changed Signal: At least one parameter has been changed
Sys.Program Mode Bypass Signal: Short-period bypass of the Program Mode.
Sys.Maint Mode Active Signal: Arc Flash Reduction Maintenance Active
Sys.Maint Mode Inactive Signal: Arc Flash Reduction Maintenance Inactive
Sys.MaintMode Manually Signal: Arc Flash Reduction Maintenance Manual Mode