LMR PLUS Electric Fire Pump Controllers with Transfer Switch
Features
1 - 1
For more information visit: www.ch re.com
BR05805063K/K
January 2012
FT80 Reduced Voltage - Wye Delta (Star-Delta) Closed
The Automatic Transfer Switch Option may be
added to any FD type Fire Pump Controller
whenever automatic transfer from normal to
alternate power is required.
The automatic Transfer Switch and Fire Pump
Controller are mounted in the same enclosure
or in separate enclosures to form one unit and
interwired - depending on the horsepower and
voltage required.
Product Description
Product Features
Engine Test Button
Logic Controller Board
Power I/O Board
Electrically and Mechani-
cally Interlocked
ATC-300 Plus
Automatic Transfer
Voltage and Frequency Sensing
Alarm Relay
Keypad Programming
LED Status Indication
An engine test button is provided on the ATC-
300 controller that can be used to test the
Source 2 (generator) engine. The operator can
select the engine run test time (0-600 minutes).
As well, a silence pushbutton is provided which
de-energizes the alarm bell.
The FT Series transfer switch operating mecha-
nisms are mechanically interlocked to prevent
the normal and alternate source from connect-
ing at the same time.
The switch operates upon signals received from
the ATC-300 Plus controller.
The panel mounted,
multi-function, micropro-
cessor based ATC-300
Plus controller accurately
monitors two power
sources and provides the
necessary intelligence
to reliably operate the
transfer switch through
a series of programmed
sensing and timing func-
tions.
The ATC-300 Plus controller membrane is
equipped with seven keypad input buttons
which are used to program the controller as well
as set operating parameters.
Five LED’s indicate the status of the power
sources.
Source 1 Available Source 1 Connected
Source 2 Available Source 2 Connected
Unit Status
The FT Series Transfer Switches
will perform an automatic
transfer from Normal to Alter-
nate source when the Voltage
drops to 85% of normal, or
there is a loss of any phase
and/or Phase Reversal.
The ATC-300 Plus continuously monitors the
normal source for out of range setpoint values.
When the source is outside the dropout set-
points, the source will become unavailable.
This prompts a transfer to the alternate source.
Retransfer occurs when the normal source’s
frequency and/or voltage return within pickup
setpoints.
The alarm relay is de-energized to indicate an
absence of an alarm state and energized to
indicate the presence of an alarm condition.
Alarm conditions include:
Improper Circuit Breaker Operation
Motor Operator Failure
Lockout
Failsafe Condition
Aborted Engine Test
Aborted Plant Exerciser
Unsuccessful in-phase Transition
The FT80 Transfer Switch Controllers use a
method of connecting the pump motor windings
into wye con guration to start, then switching to
a delta con guration to run.
This reduces the starting current of the motor
signi cantly.
Wye-Delta starting is the only method that has
a starting torque ef ciency of 100%. The FT80
can be programmed for either fully automatic or
semi-automatic operations.
Communication
The controller can be ordered with the option to
display and output current values and status,
on command, from various software protocols
through the appropriate port(s).
Embedded Web Page
The web page is a multifunction tool that allows
the user to view the controller’s current status,
data values, programmed set points and history.
It is accessed using the optional ethernet port.
USB Port / USB Drive
The logic controller board is equipped with a
USB port that can be used to transfer data to
and from a portable USB Drive device (memory
stick).
Ethernet Port
An optional ethernet port is used for direct con-
nection to a computer for data transfer.
RS485 Serial Port
An optional RS485 serial port can be provided
for communication to various external software
programs.
Buzzer
A buzzer is mounted on the logic board which
will operate if Fail to Start, Hardware Malfunc-
tion or any Common Alarm condition exists.
Transformers
Incoming line voltage is run directly to the I/O
board from the incoming lines. The three trans-
formers mounted on the I/O board will accept
voltage inputs between 100 and 600V.
Customer Connection Terminals
Connection terminals for external customer
connections, are located on the top of the
Power I/O board.
Output Relays
Seven socket mount,
8 Amp, 2 Form - C
(DPDT) output relays
are provided standard
on each power I/O board.
They are designated for:
Common Alarm,
Phase Failure,
Phase Reversal,
Pump Run,
Startup,
Acceleration
and Future # 1.
Each socket has an LED mounted on the I/O
board which indicates each relay’s coil status.
Optional Output Relay Boards
There is provision to add up to eight additional
relay outputs, via optional relay output boards.
Each board contains a maximum of 2 addi-
tional relays. The Power I/O Board will accept a
maximum of 4 optional boards which mount in a
snap-on con guration.
Each board provides an area for the user to
label the terminal number and relay name.

Other manuals for Eaton LMR PLUS

Question and Answer IconNeed help?

Do you have a question about the Eaton LMR PLUS and is the answer not in the manual?

Eaton LMR PLUS Specifications

General IconGeneral
Product NameEaton LMR PLUS
CategoryController
ManufacturerEaton
ProtocolsModbus RTU/ASCII, Modbus TCP
Frequency50/60 Hz
Power Rating5W
Operating Temperature-20° to +70°C
Protection ClassIP20
Dimensions90 x 72 x 60 mm
Weight150g
CommunicationModbus RTU/ASCII, Ethernet Modbus TCP

Summary

LMR PLUS Controller Features

Mechanical Interlock System

Ensures normal and alternate sources are not connected simultaneously via mechanical interlocking.

ATC-300 Plus Control Module

Microprocessor-based controller for monitoring and controlling power sources.

Automatic Transfer and Sensing Logic

Monitors voltage/frequency for automatic transfer and retransfer between sources.

Wye-Delta Motor Starting Method

Reduces motor starting current by connecting windings in wye then delta.

Controller Interface Overview

Main Display Functionality

Programming and System Configuration

LMR PLUS Main Display Overview

Status Indicator LEDs

Displays status of Power On, Pump Running, Local/Remote Start, Deluge Valve, Emergency Start, Interlock, Low Pressure, Auto Shutdown.

Alarm Indicator LEDs

Displays status of Phase Reversal, Phase Failure, Fail to Start, Undervoltage, Overvoltage, Low Room Temp, Locked Rotor Trip, Low Suction Pressure, Source 2 Disconnected.

ATC-300 Plus Display Functions

Source Status and Unit Display

Shows Source 1 and Source 2 availability and connection status, along with Unit Status.

Electrical Wiring Schematics

Power Transfer and Control Wiring Diagram

Detailed schematic for power transfer switch, including main power, control circuits, and wiring legends.

Customer Inputs and Alarm Contact Wiring

Diagrams for customer inputs, option relays, and alarm contacts for various fault conditions.

Internal Connection Wiring

Shows internal connections for ATS, logic board, drain valve, and buzzer.

Wiring Details and Technical Data

ATS Wiring Diagram Specifics

Shows specific wiring for ATS functions like engine start, transfer switch status, and isolating switch.

Incoming Cable Termination Specs

Table of line terminals, cable sizes, and ground lug requirements for incoming power cables.

Field Connections and Wiring Guide

Electric Motor Connection Diagrams

Wye-Delta Lower Voltage Motor Wiring

Diagram for connecting motor leads for lower nameplate voltage Wye-Delta configurations.

Wye-Delta Higher Voltage Motor Wiring

Diagram for connecting motor leads for higher nameplate voltage Wye-Delta configurations.

ATS Electrical Wiring Schematic

ATS Main Electrical Schematic

Comprehensive schematic showing utility inputs, controller, and transfer pack wiring.

Part Number and Options Selection

Selection of Available Feature Options

Lists various optional features such as enclosures, communication, special switches, and accessories.

Transfer Switch Specifications

Enclosure and Microprocessor Control Details

Specifies enclosure types and describes the solid-state control logic, sensing, and adjustable set points.

Fire Pump Controller Specifications

Microprocessor Control Features

Details LCD display functions, statistics, diagnostics, messages, custom messages, and LED status.

LMR Plus Controller Features Overview

Programming Menu Structure and Options

Covers password protection, language options, and structured menu headings for configuration.

Specific Controller Feature Details

Related product manuals