XS series operating manual 
 
XS user manual v0.55  - 35 - 
Available accessories and options  
 
  TE54     hand held HV probe 50VA (DXS50, RXS50, SXS50) 
  TE58-XS     hand held HV probe with remote control 50VA (DXS50, RXS50, SXS50) 
  TE65     hand held HV probe  500VA (DXS500, RXS500, SXS500) 
  TE66     groung continuity measurement set with CO183 and CO184 (SXS50, SXS500) 
  TE81-XS     ground continuity probe with remote control and PASS/FAIL indication for multiple  
     continuity feature.  
  TE83-XS     HV 500VA test pistol with remote control . 
  TE86-XS     HV 50VA test pistol with remote control. 
  CO160-XS    red/green lamp to indicate when HV is on 
  CO174     external box equipped with a female european mains socket 50VA (DXS50,  
RXS50, SXS50)  
  CO175     return of measurement lead  (DXS50, RXS50, SXS50, SXS500) 
  CO177     HV measurement lead for automatic test systems connection (only for 50VA) 
  CO179     RS232C interface cable. 
  CO180     HV measurement lead for automatic test systems connection (only for 500VA) 
  CO183     2 wires cable for continuity measurement with crocodile clip (SXS50, SXS500) 
  CO184     2 wires cable for continuity measurement with retractable tip probe (SXS50,  
SXS500) 
  CO185     external box equipped with female French socket 500VA (DXS500, RXS500,  
SXS500) 
  CO192     external box equipped with 6 x female different country socket 50VA (DXS50,  
RXS50, SXS50). 
  CO193     external box equipped with 6 x female different country socket  500VA (DXS500, 
RXS500, SXS500). 
  CO200 à CO209 : external box equipped with female foreign socket 50 or 500VA. 
  CO210     return pistol. 
  AO10-XS     remote control operating with 2 hands 
  AO11-XS     remote control footswitch. 
  KRXS     rack mounting kit 
  OPTION XS-02   PLC (programmable logic controler) interface 
  OPTION XS-03   0-10 volts analog input/output (DXS50, RXS50) 
  OPTION XS-04   test sequence (DXS50, DXS500) 
  OPTION XS-05   measurement input/output on the rear panel 
  OPTION XS-06     IEEE 488 interface 
  OPTION XS-07     3mA AC/DC current limitation 
  OPTION XS-08   PLC interface  + 0-10 volts analog input/output 
  OPTION XS-10   6000VDC 20VA (DXS50, RXS50, SXS50) 
  OPTION XS-13   6000VDC 200VA (RXS500, DXS500, SXS500) 
  OPTION XS-20   insulation  resistance  measurement  up  to  2  TΩ (DXS50,  DXS500,  SXS50, 
SXS500) 
  OPTION XS-22   insulation resistance measurement display in (MΩ x km) (DXS50, SXS50,  
 SXS500) 
  OPTION XS-100   ETHERNET interface 
  OPTION XS-101   ETHERNET + IEEE 488 interfaces 
  OPTION XS-26   insulation resistance measurement with voltage from 20VDC up to 1000VDC. 
 
  XS-90     technical manual with schematics 
  XS-91-1     calibration kit for hipot AC/DC 50VA function  
  XS-91-2     calibration kit for hipot AC/DC 500VA function 
  XS-91-3     calibration kit for insulation resistance function 
  XS-91-4     calibration kit for ground continuity function