150 170 210 250 300
Primary ow rate W50-W85-W112-HW140
Pump
Connecon size Heang/DHA (mm)
DHW Expansion vessel (litres) 12 18 18 24 24
Charge pressure (MPa (bar))
Control thermistor (
o
C)
Pressue Relief Valve (MPa (bar))
Control thermistor (
o
C)
Over-temperature cut-out (
o
C)
Temp/Pressure Relief Valve (
o
C/MPa (bar))
Expansion valve (MPa (bar))
Width
Depth
Height
Vessel
Type
Nominal thickness (mm)
Standing heat loss (kWh/24h)
Ozone Depl
eon Potenal
Global Warming Potenal
Electrical supply
Phase
Fuse rang - MCB Size (A)
Electrical supply
Phase
Rang (kW at 240V)
Max current (A)
Fuse rang - MCB Size (A)
PAR-WT50-E controller & PAR-WR51-E receiver
zero
3.1
220 - 240 V ~ , 50Hz
single
10
220 - 240 V ~ , 50Hz
single
3
13
DHW and 1 heang zone
80 +/- 5
90 / 1.0 (10.0)
0.8 (8.0)
Duplex stainless steel
Expanded polyurethane (PU)
60
Mechanical zones
Oponal wireles room thermostat and wireless receiver
STANDARD
0.35 (3.5)
22
Primary - 1 x Grundfos UPM3 + 1 x UPMGEO OR
1 x UPMXL GEO
DHW - Grundfos UPSO 15-60 CIL2
14.3 - 25.8 - 32.1 - 40.1 l/min
1-80
0.3 (3.0)
40 - 70
Dimensions (mm)
Weight empty/full (kg)
Materials
Insulaon
Electrical data
Control Board
(oponally powered
by outdoor unit)
Immersion heater
UNIT
Nominal hot water capacity (litres)
Water
Safety devices Primary circuit
DHW circuit
683 683 683 683 683
730 730 730 730 730
1130 1256 1508 1760 2074
1.19 1.32 1.57 1.67 1.89
56 / 206 62 / 232 69 / 279 77 / 327 87 / 387
Table 2 - STANDARD Cylinder Technical Data