EasyManua.ls Logo

Ecoer EAHAEC-36 - Page 41

Ecoer EAHAEC-36
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41/157
SDi Decades Extreme Service Manual www.ecoer.com
May. 2023Manufacturer reserves the right to change specifications or designs without notice.
4. Unplug temperature sensors T1,T2,T2A,T2B and
electronic expansion valve(EEV) from the control
board.
T1: Room temperature sensor
T2: Evaporator central temperature sensor
T2A: Evaporator input temperature sensor(only
available for some models)
T2B: Evaporator output temperature sensor(only
available for some models)
7. Adjust the position of the mounting parts.
5. Remove T1,T2,T2A,T2B sensor,EEV wire ties.
6. Take out the evaporator and drain pan and rotate 180
o
.
8. Reinstall the evaporator and drain pan.
T2
T2A&T2B
T1
EEV