Symptom
6.0 TROUBLESHOOTING
ActionCause or Failure Mode
6.1. Pumps will not run when palm
buttons on the dispenser are
depressed.
6.2. Pumps run too slow.
6.3 Pumps run too fast.
6.4 Pumps run but do not prime.
6.5 Time Totalizer needs to be
reset.
1. No "air" to the system.
1. Air pressure regulator set too low.
1. Air pressure regulator set too high.
1. Air leaks on suction side of pumps.
2. Anti-siphon valve is backwards.
1. Reset buttons on back of Total-
izer.
• Check air source
• Adjust pressure regulator
• Check the manual air valves in
dispenser
• Adjust pressure regulator to a
higher pressure
• Adjust pressure regulator to a lower
pressure
• Check suction tubing and connec-
tions for air leaks.
• Observe direction of flow arrow on
antiphon valve and turn around if
necessary.
• Open door of dispenser and de-
press the reset buttons on the back
of totalizer.
6