120 Volt 60 Hz 15 AMP Fuse or Circuit Breaker.
An individual branch circuit serving only the LaundryPure unit is recommended.
LaundryPure is equipped with a power cord.
NEVER USE AN EXTENSION CORD.
ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.
For your personal safety, this appliance must be grounded. This appliance is equipped with a
power cord having a 3-prong grounding plug for use in a properly installed and grounded outlet.
To minimize possible shock hazard, the power cord must be plugged into a mating, 3-prong,
ground-type outlet, grounded in accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and obligation of the customer to have the
properly grounded outlet installed by a qualified electrician.
As with most major appliances, use of a GFI (Ground Fault Circuit Interrupt) is not recommended.
Water pressure of 10 to 75 psi is required to correctly operate your LaundryPure. Low water
pressure may prevent your unit from operating properly and/or cause a failure in your washing
machine’s water valve. The washer’s water valve may also not shut off completely. Check the
documentation supplied with your washing machine for exact specifications.
Your washing machine and cold water faucet must be within 4 feet of the right side of the unit to
use the inlet hose provided with your LaundryPure.
TO AVOID THE POSSIBILITY OF WATER DAMAGE, SHOULD A HOSE LEAK, ALWAYS HAVE FAUCETS
ACCESSIBLE AND TURN OFF FAUCETS WHEN WASHER IS NOT IN USE.
Water quality may affect the performance of your LaundryPure unit. If you have water quality
concerns such as high iron content or high chlorine content, consult a water filtration expert.
This system is designed for use on potable water systems only.
It is recommended the LaundryPure never be installed in areas where water may freeze since
the unit will always maintain some water in the unit, the water valve, and hose areas. This can
cause damage to internal components.
ELECTRICAL REQUIREMENTS
WATER REQUIREMENTS
LOCATION CONSIDERATIONS
I N S T A L L A T I O N R E Q U I R E M E N T S
Electrical Shock Hazard.
Improper connection of the equipment-grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the
appliance is properly grounded. Do not modify the plug provided with the appliance - if it
will not fit the outlet, have a proper outlet installed by a qualified electrician.
WARNING: